m24lr64-r STMicroelectronics, m24lr64-r Datasheet - Page 71

no-image

m24lr64-r

Manufacturer Part Number
m24lr64-r
Description
64 Kbit Eeprom With Password Protection & Dual Interface 400 Khz I?c Serial Bus & Iso 15693 Rf Protocol At 13.56 Mhz
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
m24lr64-rDW6T/2
Manufacturer:
ST
0
Part Number:
m24lr64-rMB6T/2
Manufacturer:
ST
0
Part Number:
m24lr64-rMC6T/2
Manufacturer:
ST
0
Part Number:
m24lr64-rMC6TG
Manufacturer:
ST
Quantity:
20 000
Part Number:
m24lr64-rMC6TG/2
Manufacturer:
ST
Quantity:
20 000
Part Number:
m24lr64-rMN6T
Manufacturer:
ST
0
Part Number:
m24lr64-rMN6T/2
Manufacturer:
STMicroelectronics
Quantity:
4
Part Number:
m24lr64-rMN6T/2
Manufacturer:
ST
0
Part Number:
m24lr64-rMN6T/2
Quantity:
2
M24LR64-R
24
Inventory Initiated command
The M24LR64-R provides a special feature to improve the inventory time response of
moving tags using the Initiate_flag value. This flag, controlled by the Initiate command,
allows tags to answer to Inventory Initiated commands.
For applications in which multiple tags are moving in front of a reader, it is possible to miss
tags using the standard inventory command. The reason is that the inventory sequence has
to be performed on a global tree search. For example, a tag with a particular UID value may
have to wait the run of a long tree search before being inventoried. If the delay is too long,
the tag may be out of the field before it has been detected.
Using the Initiate command, the inventory sequence is optimized. When multiple tags are
moving in front of a reader, the ones which are within the reader field will be initiated by the
Initiate command. In this case, a small batch of tags will answer to the Inventory Initiated
command which will optimize the time necessary to identify all the tags. When finished, the
reader has to issue a new Initiate command in order to initiate a new small batch of tags
which are new inside the reader field.
It is also possible to reduce the inventory sequence time using the Fast Initiate and Fast
Inventory Initiated commands. These commands allow the M24LR64-Rs to increase their
response data rate by a factor of 2, up to 53 Kbit/s.
Doc ID 15170 Rev 9
Inventory Initiated command
71/126

Related parts for m24lr64-r