ox16c954 ETC-unknow, ox16c954 Datasheet - Page 24

no-image

ox16c954

Manufacturer Part Number
ox16c954
Description
High Performance Quad Uart With 128-byte Fifos Intel / Motorola Bus Interface
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ox16c954-PCC60
Manufacturer:
Omnivision
Quantity:
12 388
Part Number:
ox16c954-PCC60-B
Manufacturer:
BROADCOM
Quantity:
50
Part Number:
ox16c954-PCC60-B
Manufacturer:
OXFORD
Quantity:
3 054
Part Number:
ox16c954-PLBG
Manufacturer:
ROHM
Quantity:
1 001
Part Number:
ox16c954-PLBG
Manufacturer:
OXFORD
Quantity:
1 176
Part Number:
ox16c954-TQBG
Manufacturer:
XILINX
Quantity:
101
Part Number:
ox16c954-TQC60-B
Manufacturer:
VICOR
Quantity:
120
Part Number:
ox16c954-TQC60-B
Manufacturer:
ALTERA
0
Part Number:
ox16c954PLBG
Manufacturer:
OXFORO
Quantity:
20 000
The transmitter interrupt trigger levels are set to 1 and
FCR[5:4] are ignored.
650 mode:
In 650 mode the transmitter interrupt trigger levels can be
set to the following values:
These levels only apply when in Enhanced mode and in
DMA mode 1(FCR[3] = 1), otherwise the trigger level is set
to 1. A transmitter empty interrupt will be generated (if
enabled) if the TFL falls below the trigger level.
750 Mode:
In 750 compatible non-enhanced (EFR[4] = 0) mode,
transmitter trigger level is set to 1, FCR[4] is unused and
FCR[5] defines the FIFO depth as follows:
FCR[5]=0 Transmitter and receiver FIFO size is 16 bytes.
FCR[5]=1 Transmitter and receiver FIFO size is 128 bytes.
In non-Enhanced mode and when FIFOSEL# pin is high,
FCR[5] is writable only when LCR[7] is set. Note that in
Enhanced mode, the FIFO size is increased to 128 bytes
when FCR[0] is set.
9
9.1
On the falling edge of a start bit, the receiver will wait for
1/2 bit and re-synchronise the receiver’s sampling clock
onto the centre of the start bit. The start bit is valid if the
SIN line is still low at this mid-bit sample and the receiver
will proceed to read in a data character. Verifying the start
bit prevents noise generating spurious character
generation.
Once the first stop bit has been sampled, the received data
is transferred to the RHR and the receiver will then wait for
a low transition on SIN (signifying the next start bit).
The receiver will continue receiving data even if the RHR is
full or the receiver has been disabled (see section 15.3) in
order to maintain framing synchronisation. The only
Data Sheet Revision 1.0
450, 550 and extended 550 modes:
OXFORD SEMICONDUCTOR LTD.
FCR[5:4]
L
Table 9: Transmit Interrupt Trigger Levels
INE
False Start Bit Detection
00
01
10
11
C
ONTROL
Transmit Interrupt Trigger level
& S
TATUS
112
16
32
64
950 mode:
Setting ACR[5]=1 enables 950-mode trigger levels set
using the TTL register (see section 15.4), FCR[5:4] are
ignored.
FCR[7:6]: RHR trigger level
In 550, 450, 550, extended 550, 650 and 750 modes:
The receiver FIFO trigger levels are defined using
FCR[7:6]. The interrupt trigger level and upper flow control
trigger level where appropriate are defined by L1 in the
table below. L2 defines the lower flow control trigger level.
Separate upper and lower flow control trigger levels
introduce a hysteresis element in in-band and out-of-band
flow control (see section 13). In Byte mode (450 mode) the
trigger levels are all set to 1.
950 mode:
In similar fashion to for transmitter trigger levels, setting
ACR[5]=1 enables 950-mode receiver trigger levels.
FCR[7:6] are ignored.
A receiver data interrupt will be generated (if enabled) if the
Receiver FIFO Level (‘RFL’) reaches the upper trigger
level.
difference is that the received data does not get transferred
to the RHR.
9.2
The LCR specifies the data format that is common to both
transmitter and receiver. Writing 0xBF to LCR enables
access to the EFR, XON1, XOFF1, XON2 and XOFF2,
DLL and DLM registers. This value (0xBF) corresponds to
an unused data format. Writing the value 0xBF to LCR will
set LCR[7] but leaves LCR[6:0] unchanged. Therefore, the
data format of the transmitter and receiver data is not
affected. Write the desired LCR value to exit from this
selection.
FCR
00
01
10
11
Table 10: Compatible Receiver Trigger Levels
Line Control Register ‘LCR’
FIFO Size 16
L1
14
1
4
8
550
n/a
n/a
n/a
n/a
L2
Ext. 550 / 750
112
L1
32
64
FIFO Size 128
1
Mode
L2
1
1
1
1
OX16C954 rev B
FIFO Size 128
112
120
L1
16
32
650
Page 24
112
L2
16
32
1

Related parts for ox16c954