msm9225 Oki Semiconductor, msm9225 Datasheet - Page 13

no-image

msm9225

Manufacturer Part Number
msm9225
Description
Can Controller Area Network Controller
Manufacturer
Oki Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
msm9225B
Manufacturer:
MICREL
Quantity:
6 246
Part Number:
msm9225BGA-2K
Manufacturer:
OKI
Quantity:
5 000
¡ Semiconductor
1. CAN control register (CANC: 0Ehex)
(1) Initialize: INIT
(2) Transmission identifier retrieval: TIRS
(3) Bit synchronization: SYNC
This register controls the operation of CAN.
The bit configuration is as follows:
This bit is used to initialize the communication control area. To start initialization, write
If the INIT bit is set to "1" during the transmission or receive operation, the initialization
will start after the communication completes.
When the INIT bit is set to "1", the communication operation stops but the error counter
and data memory are held.
To initialize message memory, write the number of messages to be used to the number
of messages setting register, NMES, then write the inside message control register,
identifier 1, and identifier 2 sequentially from message 0 for all messages.
At reset, INIT is set to "1".
no transmission request messages after scanning or transmitting.
At reset, TIRS is set to "0".
data.
"1" to INIT, read INIT and confirm that INIT is "1", then initialize. To end initialization,
write "0" to INIT, read INIT, and confirm that INIT is "0". For both, initialization mode
is not set/cleared until the above procedure is executed.
This bit is used to scan identifiers sequentially from message 0 to the last message of the
message memory, detecting priority of the message for which the transmission request
TRQ is "1" and starting to transmit the messages. TIRS will be set to "0" when there are
This bit is used to set the bit synchronization edge to synchronize at the CAN bus.
When SYNC is "0", the synchronization edge is set at the falling edge of data.
When SYNC is "1", the synchronization edge is set at both the rising and falling edges of
At reset, SYNC is set to "0".
0Eh
Address MSB
7
6
5
4
3
2
1
LSB
0
INIT : Initialize
TIRS : Transmission identifier retrieval
Not used
SYNC : Bit synchronization
CANA : CAN write flag
T x F : Transmission flag
R x F : Receive flag
Not used
MSM9225
13/73