■ List of Settings
Fill in your set values in the set value column of the following tables and utilize the tables for quick reference.
Timer/Twin Timer Selection Mode
Settings for Timer Operation
Run Mode when Output Mode Is Not Z
Run Mode when Output Mode = Z
Function Setting Mode
Timer/Twin Tim-
er selection
DIP switch moni-
tor
Present value,
set value
Present value,
ON duty ratio
Present value,
cycle time
Time range
Timer mode
Output mode
Output time
Input signal width
NPN/PNP input mode
Display color
Key protect level
Parameter
name
Parameter name
Parameter name
Parameter name
Cycle time
ON duty ratio
Present value
Present value
Set value
Present value
func
dip
Parameter
---
---
---
---
---
---
---
---
---
---
---
---
---
Parameter
---
---
---
---
---
---
---
---
---
---
---
tim/twin
on/off
Parameter
timr
timm
outm
otim
iflt
imod
colr
kypt
Parameter
0.00 to 99.99 (Time range: --,--s)
0.0 to 999.9 (Time range: ---,-s)
0 to 9999 (Time range: ----s)
0:00 to 99:59 (Time range: --min--s)
0.0 to 999.9 (Time range: ---,-min)
0 to 9999 (Time range: ----min)
0:00 to 99:59 (Time range: --h--min)
0.0 to 999.9 (Time range: ---,-h)
0 to 9999 (Time range: ----h)
0.000 to 9.999 (Time range: -,---s)
0 to 100
Same as cycle time above
Same as cycle time above
0.00 to 99.99 (Time range: --,--s)
0.0 to 999.9 (Time range: ---,-s)
0 to 9999 (Time range: ----s)
0:00 to 99:59 (Time range: --min--s)
0.0 to 999.9 (Time range: ---,-min)
0 to 9999 (Time range: ----min)
0:00 to 99:59 (Time range: --h--min)
0.0 to 999.9 (Time range: ---,-h)
0 to 9999 (Time range: ----h)
0.000 to 9.999 (Time range: -,---s)
Same as set value
Setting range
--.--s/---.-s/----s/--min--s/---.-min/----min/--
h--min/---.-h/----h/-.---s
up/down
a/a-1/a-2/a-3/b/b-1/d/e/f/=
hold/0.01 to 99.99
20ms/1ms
npn/pnp
red/org/r-o/o-r
kp-1/kp-2/kp-3/kp-4/kp-5
Setting range
Setting range
Setting range
tim
off
Default value
0.00
0.0
0
0:00
0.0
0
0:00
0.0
0
0.000
Same as left
0.00
0.0
0
0:00
0.0
0
0:00
0.0
0
0.000
0
Same as left
Same as left
Default value
Default value
--.--s
up
a
hold
20ms
npn
red
kp-1
Default
value
---
---
s
s
s
min; s
min
min
h; min
h
h
s
Same as left
s
s
s
min; s
min
min
h; min
h
h
s
%
Same as left
Same as left
Unit
---
---
---
s
---
---
---
---
Unit
Unit
Unit
H5CX-A/-L
Set value
Set value
Set value
Set value
33