h3ds-x Omron Corporation, h3ds-x Datasheet - Page 22

no-image

h3ds-x

Manufacturer Part Number
h3ds-x
Description
Solid-state Timer
Manufacturer
Omron Corporation
Datasheet
■ Characteristics
Note: For reference:
Accuracy of operating time ±1% max. of FS
Setting error
Total tolerance of transfer
time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
EMC
Case color
Degree of protection
Weight
A maximum current of 0.15 A can be switched at 125 VDC (cosφ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
http://www.ia.omron.com/
±10% ± 50 ms max. of FS
± (25% FS + 5 ms) max.
±0.5% max. of FS
±5% max. of FS
100 MΩ min. at 500 VDC
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60 Hz) for 1
min.
Between control output terminals and operating circuit: 2,000 VAC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 VAC (50/60 Hz) for 1 min.
3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) ±1.5 kV
Malfunction: 4 kV
Destruction: 8 kV
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Malfunction: 200 m/s
Destruction: 300 m/s
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical:
(EMI)
Emission Enclosure:
Emission AC Mains:
Harmonic Current:
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity Burst:
Immunity Surge:
Light gray (5Y7/1)
IP30 (IP20 for terminal block)
Approx. 70 g
100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) (see note)
2
2
, 3 times each in 6 directions
, 3 times each in 6 directions
EN61812-1
EN55011 Group 1 class B
EN55011 Group 1 class B
EN61000-3-2
EN61812-1
EN61000-4-2: 6 kV contact discharge (level 3)
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
EN61000-4-4: 2 kV power port and output port (level 3)
EN61000-4-5: 2 kV common mode (level 3)
8 kV air discharge (level 3)
1 kV control port with capacitive clamp (level 3)
1 kV differential mode (level 3)
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
H3DS-G
22

Related parts for h3ds-x