emc2104 Standard Microsystems Corp., emc2104 Datasheet - Page 46
emc2104
Manufacturer Part Number
emc2104
Description
Emc2104 Dual Rpm-based Pwm Fan Controller With Hardware Thermal Shutdown
Manufacturer
Standard Microsystems Corp.
Datasheet
1.EMC2104.pdf
(101 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Revision 1.74 (05-08-08)
ADDR
9Ch
9Dh
92h
93h
94h
95h
96h
97h
98h
99h
9Ah
9Bh
9Eh
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
LUT 2 Temp 1
LUT 2 Temp 2
LUT 2 Temp 3
LUT 2 Temp 4
LUT 2 Temp 1
LUT 2 Temp 2
LUT 2 Temp 3
LUT 2 Temp 4
LUT 2 Temp 1
LUT 2 Temp 2
LUT 2 Temp 3
LUT 2 Drive 2
LUT 2 Drive 3
REGISTER
Setting 1
Setting 1
Setting 1
Setting 1
Setting 2
Setting 2
Setting 2
Setting 2
Setting 3
Setting 3
Setting 3
NAME
Table 6.1 EMC2104 Register Set (continued)
External Diode 1 (or VIN1) channel that
External Diode 2 (or VIN2) channel that
temp) that is associated with the Drive 1
Temp 4 temp) that is associated with the
External Diode 2 (or VIN2) channel that
temp) that is associated with the Drive 2
Temp 4 temp) that is associated with the
External Diode 1 (or VIN1) channel that
External Diode 2 (or VIN2) channel that
temp) that is associated with the Drive 3
External Diode 1 (or VIN1)channel that
TRIP_SET voltage or Pushed Temp 3
TRIP_SET voltage or Pushed Temp 3
TRIP_SET voltage or Pushed Temp 3
External Diode 3 channel (or VIN3 or
External Diode 3 channel (or VIN3 or
External Diode 3 channel (or VIN3 or
Stores the second programmed drive
is associated with the Drive 1 value
is associated with the Drive 1 value
is associated with the Drive 2 value
is associated with the Drive 2 value
is associated with the Drive 3 value
is associated with the Drive 3 value
Internal Diode channel (or Pushed
Internal Diode channel (or Pushed
Stores the third programmed drive
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
Stores the threshold level for the
DATASHEET
setting for LUT 2
setting for LUT 2
Dual RPM-Based PWM Fan Controller with Hardware Thermal Shutdown
Drive 1 value
Drive 2 value
FUNCTION
46
value
value
value
DEFAULT
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
(127°C)
VALUE
E6h
D1h
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
7Fh
Lock 2
Lock 2
Lock 2
Lock 2
Lock 2
Lock 2
Lock 2
Lock 2
Lock 2
Lock 2
Lock 2
Lock 2
Lock 2
LOCK
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
LUT
SMSC EMC2104
Page 78
Page 78
Page 78
Page 78
Page 78
Page 78
Page 78
Page 78
Page 78
Page 78
Page 78
Page 78
Page 78
Datasheet
PAGE