5.2.2.4. FIFO Clearing
Table below summarizes the status of the FIFO when switching between different modes
Table 20 Status of FIFO when Switching Between Different Modes of the Chip
5.2.3. Sync Word Recognition
5.2.3.1. Overview
Sync word recognition (also called Pattern recognition) is activated by setting SyncOn in RegSyncConfig. The bit
synchronizer must also be activated in continuous mode (automatically done in Packet mode) .
The block behaves like a shift register; it continuously compares the incoming data with its internally programmed Sync
word and sets SyncAddressMatch when a match is detected. This is illustrated in Figure 28 below.
Rev 1 - Oct 2011
ADVANCED COMMUNICATIONS & SENSING
Stdby/Sleep
Stdby/Sleep
Stdby
Sleep
From
- FifoLevel interrupt is updated only after a read or write operation on the FIFO. Thus the interrupt cannot be
dynamically updated by only changing the FifoThreshold parameter
- FifoLevel interrupt is valid as long as FifoFull does not occur. An empty FIFO will restore its normal operation
Rx
Rx
Tx
Stdby/Sleep
FifoLevel
Sleep
Stdby
Any
To
Rx
Tx
Tx
1
0
FIFO status
Not cleared
Not cleared
Not cleared
Not cleared
Figure 27. FifoLevel IRQ Source Behavior
Cleared
Cleared
Cleared
Page 46
To allow the user to read FIFO in Stdby/Sleep mode after Rx
To allow the user to write the FIFO in Stdby/Sleep before Tx
B
B+1
Comments
# of bytes in FIFO