zws150pf TDK Corp., zws150pf Datasheet - Page 10

no-image

zws150pf

Manufacturer Part Number
zws150pf
Description
Single Output 5w - 300w
Manufacturer
TDK Corp.
Datasheet
ZWS
A-412
ZWS
(*10) Please refer to Fig A for measurement of line & load regulation
(*11) At standard mounting method, Fig B.
Environment
Standards
Mechanical
Function
Isolation
ITEMS/UNITS
(*1) Operating time at peak output is less than 10 seconds. (Duty=0.35)
(*2) At 100VAC and maximum output current, Ta=25℃.
(*3) For cases where conformance to various safety specs (UL, CSA) are required, to be described as 100 - 240VAC,
(*4) From 85 - 265VAC and constant load.
(*5) From Min load - Full load (maximum power) and constant input voltage.
(*6) From -10 to +50℃ constant input voltage and load.
(*7) Current limiting with automatic recovery.
(*8) OVP circuit will shutdown ouput, manual reset.
(*9) Refer to instruction manual.
Output
Input
50/60Hz on name plate.
Avoid to operate over load or dead short for 30 seconds.
and ripple voltage.
Voltage Range
Frequency
Efficiency (typ)
Current (100/200VAC)(typ)
Inrush Current (100/200VAC)(typ)
Nominal Voltage
Minimum Current
Maximum Current
Maximum Peak Current
Maximum Power
Maximum Peak Power
Maximum Line Regulation (*4)(*10) mV
Maximum Load Regulation (*5)(*10) mV
Temperature Coefficient
Maximum Ripple & Noise (0 to +60℃) (*10) mVp-p
Maximum Ripple & Noise (-10 to 0℃) (*10) mVp-p
Hold-up Time (100VAC)(typ)
Voltage Adjustable Range
Over Current Protection
Over Voltage Protection
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Cooling
Withstand Voltage
Isolation Resistance
Safety Standards
EMI
Weight (typ)
Size (W x H x D)
Bandwidth of scope:100MHz
50

C1:Elec.Cap 100uF
C2:Film Cap 1uF
L:150mmAWG#18x2
Measurement point
C2
for Vripple
COMPONENT SIDE
C1
Fig.A
Fig.B
(*11)
(*3)
(*3) Hz
(*2)
(*6) mV
(*2) ms
(*7)
(*8)
(*9)
(*1)
(*1)
MODEL
Measurement point for Vo,
Line/Load Regulation.
%RH
%RH
VDC
L
mm
W
W
V
A
A
A
A
A
g
ZWS50 Specifications
ZWS50-3
PCB
39.60
33.0
3.3
73
Bandwidth of scope:100MHz
CN2
Approved by UL60950-1, CSA C22.2 No 60950-1, EN60950-1. Built to meet DENAN.
12.0
160
C1:Elec.Cap 100uF
C2:Film Cap 1uF
120
60
10
20
40
L:150mmAWG#18x2
ZWS50-5
60.00
50.0
Measurement point
77
More than 100MΩ at 25℃ and 70%RH Output - FG 500VDC
5
C2
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
10-55Hz (sweep 1min) less than 19.6m/s² X,Y,Z 1h each
for Vripple
COMPONENT SIDE
C1
Built to meet EN55022-B, FCC-ClassB, VCCI-B
ZWS50-12 ZWS50-15 ZWS50-24 ZWS50-36 ZWS50-48
Output - FG : 500VAC (100mA) for 1min
Fig.A
Fig.B
61.92
5.16
51.6
140
4.3
80
12
48
96
15 / 30 at, Ta=25℃, cold start
17 at 100VAC, 50W, Ta=25℃
-10 to +50 : 100%, +60 : 70%
AC85 - 265 or DC110 - 330
Measurement point for Vo,
Line/Load Regulation.
Less than 196.1m/s²
Convection cooling
L
150
180
55 x 26 x 195
115% - 135%
-30 to +85
Possible
47 - 440
1.4 / 0.7
>125%
30 - 90
10 - 95
±10%
63.00
4.20
52.5
PCB
120
180
360
3.5
81
15
60
0
-
・All specifications are subject to change without notice.
CN2
2.52
150
280
200
200
2.1
24
96
●Recommended EMC Filter
Please refer to "TDK-Lambda
EMC Filters" catalog.
RSEL-2002W
60.48
50.4
1.68
144
240
420
300
300
1.4
82
36
63.36
52.8
1.32
192
300
560
400
400
1.1
48

Related parts for zws150pf