zws150pf TDK Corp., zws150pf Datasheet - Page 33

no-image

zws150pf

Manufacturer Part Number
zws150pf
Description
Single Output 5w - 300w
Manufacturer
TDK Corp.
Datasheet
・All specifications are subject to change without notice.
ZWS-AF
*Connector for Remote ON/OFF Control : CN2, CN52 (J.S.T)
CN2 is normally shorted by JM-2W-96 (J.S.T) .
Hand Crimping Tool : YC-110R (J.S.T) or YRS-110 (J.S.T)
*Input & Output Connector (MOLEX)
CN53 is used only for ZWS150AF.
Hand Crimping Tool : JHTR2445A (MOLEX)
*ZWS-AF/J Input & Output Connector (J.S.T)
CN53 is used only for ZWS150AF.
Hand Crimping Tool : YC-160R (J.S.T)
Pin-order of J.S.T connectors are opposite to pin-order of MOLEX. Please refer to outline drawing.
1 Input Voltage Range
Input voltage range is single phase 85-265VAC (47-63Hz)
or 120-370VDC. Input voltage which is out of specification
may cause unit damage. For cases where conformance to
various safety specs (UL, CSA, EN) are required, input volt-
age range will be 100-240VAC (50/60Hz) .
2 Output Voltage Range
V.ADJ trimmer (VR51) near output connector can adjust the
output voltage within the range. Output voltage range is
within ±10% of nominal output voltage. To turn the trim-
mer clockwise, the output voltage will be increased. Note
over voltage protection ( OVP) function may trigger if the
output voltage is increased excessively.
3 Inrush Current
This series has used Power Thermistor to protect the
circuit from inrush current. Please carefully select input
switch and fuse in cases of the high temperature and re-
input the power.
4 Over Voltage Protection (OVP)
The OVP function (inverter shut down method, manual
Output : CN51
Output : CN51
Output : CN51
Output : CN51
Input : CN51
B2B-XH-AM
Input : CN1
Input : CN1
Input : CN1
Connector
CN53
CN53
3. Explanation of Functions and Precautions
5414-30B
5273-04A
5414-30B
5273-08A
Connector
Connector
Connector
B3P-5-VH
Connector
B3P-5-VH
Housing
B4P-VH
B8P-VH
XHP-2
ZWS100AF/J
ZWS50AF/J
ZXWS50AF
ZWS100AF
5239-06
5239-04
5239-06
5239-08
Housing
Housing
Housing
VHR-5N
VHR-4N
Housing
VHR-5N
VHR-8N
BXH-001T-P0.6 or SXH-001T-P0.6
SVH-21T-P1.1
SVH-21T-P1.1
SVH-21T-P1.1
SVH-21T-P1.1
Terminal Pin
Terminal Pin
Terminal Pin
Terminal Pin
5167PBTL
5167PBTL
5167PBTL
5167PBTL
Terminal Pin
(5V type: 105%) of maximum output current of specifica-
reset type) is provided. OVP function operates within
115-135% (5V type: 115-140%) of nominal output volt-
age. When OVP triggers, the output will be shut down. The
input shall be removed for a few minutes, and then re-input
for recovery of the output. OVP setting shall be fixed and
not to be adjusted externally.
5 Over Current Protection (OCP)
Constant current limiting, automatic recovery. OCP func-
tion operates when the output current exceeds 125%
tion. The output will be automatically recovered when the
overload condition is canceled. Do not operate overload
or dead short conditions for more than 30 seconds, which
could result in damage.
6 Output Ripple & Noise
The standard specification for maximum ripple value is
measured according to measurement circuit specified
by JEITA-RC9131. When load lines are longer, ripple
becomes larger. In this case, electrolytic capacitor, film
capacitor, etc., might be necessary to use across the load
terminal. The output ripple cannot be measured accurately
if the probe ground lead of oscilloscope is too long.
5414-30B
5273-06A
5414-30B
5273-06A
5273-07A
Connector
Connector
Connector
B3P-5-VH
Connector
B3P-5-VH
B6P-VH
B6P-VH
B7P-VH
ZWS150AF/J
ZWS75AF/J
ZWS150AF
ZWS75AF
5239-06
5239-06
5239-06
5239-06
5239-07
Housing
Housing
Housing
VHR-5N
VHR-6N
Housing
VHR-5N
VHR-6N
VHR-7N
SVH-21T-P1.1
SVH-21T-P1.1
SVH-21T-P1.1
SVH-21T-P1.1
SVH-21T-P1.1
Terminal Pin
Terminal Pin
Terminal Pin
Terminal Pin
5167PBTL
5167PBTL
5167PBTL
5167PBTL
5167PBTL
A-435
ZWS