w65c816s Western Design Center, Inc., w65c816s Datasheet - Page 53

no-image

w65c816s

Manufacturer Part Number
w65c816s
Description
W65c816s 8/16?bit Microprocessor
Manufacturer
Western Design Center, Inc.
Datasheet
7.6
When RDY is low, the Data Bus is held in the data transfer state (i.e. PHI2 high). The Bank address
external transparent latch should be latched on the rising edge of the PHI2 clock.
7.7
The MX output reflects the value of the M and X bits of the processor Status Register. The REP, SEP and
PLP instructions may change the state of the M and X bits. Note that the MX output is invalid during the
instruction cycle following REP, SEP and PLP instruction execution. This cycle is used as the opcode fetch
cycle of the next instruction.
7.8
instructions and addressing modes are intended for W65C816S 24-bit addressing, and are therefore less
useful for the emulation mode. The JSL, RTL, JMP al and JML instructions and addressing modes are
primarily intended for W65C816S native mode use.
Address is not multiplexed on the Data Bus: PHK, PHB and PLB
mode. In this mode the M and X bits will always be high (logic 1).
Registers for the memory address. Also, the MVP and MVN instructions can only move data within the
memory range 0000 (Source Bank) to 00FF (Destination Bank) for the W65C816S, and 0000 to 00FF for
the emulation mode.
7.9
The JMP (a) and JML (a) instructions use the direct Bank for indirect addressing, while JMP (a,x) and JSR
(a,x) use the Program Bank for indirect address tables.
7.10 Switching Modes
When switching from the Native mode to the Emulation mode, the X and M bits of the Status Register are
set high (logic 1), the high byte of the Stack is set to 01, and the high bytes of the X and Y Index
Registers are set to 00. To save previous values, these bytes must always be stored before changing
modes. Note that the low byte of the S, X and Y Registers and the low and high byte of the Accumulator
(A and B) are not affected by a mode change.
7.11 How Interrupts Affect the Program Bank and the Data Bank Registers
hardware interrupt, BRK or COP is executed. In the Native mode, previous PBR contents are automatically
saved on Stack.
interrupt, BRK or COP is executed. In this case, previous contents of the PBR are not automatically saved.
which originally generated the interrupt.
DB/BA operation when RDY is Pulled Low
MX Output
All Opcodes Function in All Modes of Operation
Indirect Jumps
7.7.1
7.7.2
7.7.3
7.7.3.1 The REP and SEP instructions cannot modify the M and X bits when in the Emulation
7.7.3.2 When in the Emulation mode, the MVP and MVN instructions use the X and Y Index
7.11.1 When in the Native mode, the Program Bank register (PBR) is cleared to 00 when a
7.11.2 In the Emulation mode, the PBR and DBR registers are cleared to 00 when a hardware
7.11.3 Note that a Return from Interrupt (RTI) should always be executed from the same "mode"
It should be noted that all opcodes function in all modes of operation. However, some
The following instructions may be used with the emulation mode even though a Bank
The following instructions have "limited" use in the Emulation mode:
53