6mbi75s-060 Fuji Electric holdings CO.,Ltd, 6mbi75s-060 Datasheet - Page 7

no-image

6mbi75s-060

Manufacturer Part Number
6mbi75s-060
Description
Igbt Module
Manufacturer
Fuji Electric holdings CO.,Ltd
Datasheet
Test
cate-
gories
Electrical
Visual
Note : Each parameter measurement read-outs shall be made after stabilizing the components
characteristic
inspection
Item
1 High temperature
2 High temperature
3 Intermitted
at room ambient for 2 hours minimum, 24 hours maximum after removal from the tests.
And in case of the wetting tests, for example, moisture resistance tests, each component
shall be made wipe or dry completely before the measurement.
(Power cycle)
( for IGBT )
Reverse Bias
Reverse Bias
Operating Life
Test items
Leakage current
Gate threshold voltage VGE(th)
Saturation voltage
Forward voltage
Thermal
Isolation voltage
Visual inspection
resistance
Peeling
Plating
and the others
Characteristic
Test temp.
Bias Voltage
Bias Method
Test duration
Test temp.
Bias Voltage
Bias Method
Test duration
ON time
OFF time
Test temp.
Number of cycles
IGBT
FWD
Reliability Test Items
Test methods and conditions
Failure Criteria
or
VCE(sat)
Symbol
±IGES
ICES
Viso
VF
VGE
VF
-
VCE
: Ta = 125
: VC = 0.8×VCES
: Applied DC voltage to C-E
: 1000hr.
: Ta = 125
: VC = VGE = +20V or -20V
: Applied DC voltage to G-E
: 1000hr.
: 2 sec.
: 18 sec.
:
: 15000 cycles
VGE = 0V
VCE = 0V
Tj ≦ 150 ℃, Ta=25±5 ℃
(Tj ≦ 150 ℃)
(Tj ≦ 150 ℃)
Tj=100±5 deg
Lower limit Upper limit
LSL×0.8
The visual sample
Broken insulation
Failure criteria
-
-
-
-
-
-
+0
+0
-5
-5
LSL : Lower specified limit.
USL : Upper specified limit.
USL×1.2
USL×1.2
USL×1.2
USL×1.2
USL×1.2
MS5F5326
USL×2
USL×2
Unit
mA
mA
mV
mV
V
V
-
-
A
Reference
ED-4701
D - 313
D - 323
D - 322
norms
EIAJ
Note
of sample
Number
5
5
5
H04-004-03
7
Accept-
ance
number
( 1 : 0 )
( 1 : 0 )
( 1 : 0 )
13