Image Sensor Characteristics Measurement Method
1) In the following measurements, the substrate voltage is set to the value indicated on the device, and the
2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical
3) In the following measurements, this image sensor is operated in 1/50s interlaced mode.
1) Standard imaging condition
2) Standard imaging condition II:
1. Sensitivity
2. Saturation signal
3. Smear
4. Video signal shading
5. Dark signal
Measurement conditions
Definition of standard imaging conditions
device drive conditions are at the typical values of the bias and clock voltage conditions.
black level (OB) is used as the reference for the signal output and the value measured at point [ A] in the
measurement system is used.
Use a pattern box (luminance 706cd/m
(Pattern for evaluation is not applicable.) Use a testing standard lens with CM500S (t = 1.00mm) as an IR
cut filter and image at F8. The luminous intensity to the sensor receiving surface at this point is defined as
the standard sensitivity testing luminous intensity.
Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles.
Use a testing standard lens with CM500S (t = 1.00mm) as an IR cut filter. The luminous intensity is
adjusted to the value indicated in each testing item by the lens diaphragm.
Set to standard imaging condition I. After selecting the electronic shutter mode with a shutter speed of
1/250s, measure the signal output (Vs) at the center of the screen and substitute the value into the
following formula.
S = Vs
Set to standard imaging condition II. After adjusting the luminous intensity to 10 times the intensity with
average value of signal output, 120mV, measure the minimum value of the signal output.
Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity to
500 times the intensity with average value of signal output, 120mV. When the readout clock is stopped and
the charge drain is executed by the electronic shutter at the respective H blankings, measure the maximum
value VSm [mV] of the signal output and substitute the value into the following formula.
Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, adjust the luminous intensity
so that the average value of the signal output is 120mV. Then measure the maximum (Vmax [mV]) and
minimum (Vmin [mV]) values of the signal output and substitute the values into the following formula.
SH = (Vmax – Vmin)/120
Measure the average value of the signal output (Vdt [mV]) with the device ambient temperature 60°C and
the device in the light-obstructed state, using the horizontal idle transfer level as a reference.
Sm =
VSm
120
250
50
500
[mV]
1
10
1
100 [%]
I:
100 [%] (1/10V method conversion value)
2
, color temperature of 3200K halogen source) as a subject.