FBK04A05L1SA PANASONIC [Panasonic Semiconductor], FBK04A05L1SA Datasheet

no-image

FBK04A05L1SA

Manufacturer Part Number
FBK04A05L1SA
Description
Locked rotor protection circuits Automatically restarts in a few seconds Reverse voltage protection
Manufacturer
PANASONIC [Panasonic Semiconductor]
Datasheet
8 – (f4.5)
Allowable Ambient Temperature Range:
Units:
.177
Rotation: Clockwise
FBA09A ( 92
-10°C ~ +70°C (65%RH) (Operating)
-40°C ~ +75°C (65%RH) (Storage)
(non-condensing environment)
(mm)
inch
FBA09A 12L
FBA09A 12M
FBA09A 12H
FBA09A 24L
FBA09A 24M
FBA09A 24H
MODEL
ROTATION
(82.5)
3.25
3.62
(92)
INLET SIDE
(82.5)
3.25
3.54
(90)
4 – (f4.7)
.185
Housing with solid corner type are available.
X
Voltage
Rated
inlet
(V)
12
12
12
24
24
24
.157
25.5
(4)
(25.5)
FLOW
1.00
14.0 ~ 27.6
14.0 ~ 27.6
14.0 ~ 27.6
OUTLET SIDE
Operating
7.0 ~ 13.8
7.0 ~ 13.8
7.0 ~ 13.8
Voltage
.157
(4)
outlet
(V)
L
(82.5)
3.25
3.54
(90)
)
4 – (f4.7)
Airfl ow Outlet: Air Out Over Struts
LR99935
.185
Current
EMINEBEA.COM
(A)
110
150
255
110
140
80
*1
PLATE
NAME
Power
Input
(W)
1.32
1.80
2.70
1.92
2.64
3.36
*1
- Pin
+ Pin
(min
Failure Rate: 10%
Speed
Rated
Bearing: Hydro Wave Bearing
2200
2450
2950
2200
2450
2900
50,000 Hours (40°C, 65%RH)
-1
)
Ps
*1
CFM
42.7
48.0
56.8
42.7
48.0
56.8
Air
60
40
20
*1
0
Max.
(Pa)
(m
Flow
1.21
1.36
1.61
1.21
1.36
1.61
3
/min)
1
*1
in H
Air Flow
*1: Average Values in Free Air
Max. Static
.10
.16
.10
.16
12V(24V)-H
.11
.11
Pressure
2
2
O
12V(24V)-M
12V(24V)-L
(Pa)
25.5
29.4
42.1
25.5
29.4
42.1
3
*1
Noise
(dB)
3000
1000
(min -
2000
(m
27.0
30.0
35.0
27.0
30.0
35.0
3
/min)
*1
1
)
N
Mass
110
110
110
110
110
110
(g)

Related parts for FBK04A05L1SA

FBK04A05L1SA Summary of contents

Page 1

FBA09A ( 92 25.5 X Allowable Ambient Temperature Range: -10°C ~ +70°C (65%RH) (Operating) -40°C ~ +75°C (65%RH) (Storage) (non-condensing environment) inch Units: (mm) .177 1.00 ROTATION 8 – (f4.5) (25.5) .157 (4) inlet FLOW 3.25 (82.5) 3.62 Housing with ...

Page 2

FEATURES Specifications of Various Sensors LOCKED ROTOR ALARM SIGNAL Signal given when fan is running PULSE PER REVOLUTION SIGNAL Signal given when fan is running Revolution 2PPR Panaflo Built-in Connector System 2 Signal ...

Page 3

High Reliability with HWB (Hydro Wave Bearing) Radial Direction shaft thrust plate bearing Figure 1: Pressure distribution in each load direction. HWB thrust plate Figure 1: Construction of HWB Panaflo’ s unique hydrowave bearing (HWB) addresses the traditional weakness of ...

Page 4

COMMON SPECIFICATIONS Noise Data Microphone Microphone Microphone * Distance 1m. 4 Protection • Locked rotor protection circuits • Automatically restarts in a few seconds • Reverse voltage protection Insulation Resistance 10M Ω minimum at 500v DC (frame to leads) • ...

Page 5

PANAFLO FAN PRODUCT DESIGNATION CODE Panaflo Fan Housing Size 04 40mm 06 60mm 08 80mm 09 92mm 12: 120 x ...

Page 6

Type Model Rated and Size Voltage (V) FBK04F FBK04F05L 5 40mm FBK04F05H 5 DC axial fans FBK04F12L 12 FBK04F12H 12 FBK04F12U 12 FBK04F24H 24 FBK04F24U 24 FBA06A FBA06A12L1A 12 60mm FBA06A12M1A 12 DC axial fans FBA06A12H1A 12 FBA06A12U1A 12 FBA06A24L1A ...

Page 7

Type Model Rated Operating and Size Voltage Voltage (V) (V) FCB34 FCB34AA12 12 10.2—13.8 Crossflo Fans FCB34AB12 12 10.2—13.8 FCB34AC12 12 10.2—13.8 FCB34AD12 12 10.2—13.8 FCB34AE12 12 10.2—13.8 FCB34AF12 12 10.2—13.8 FCB34AA24 24 20.4—27.6 FCB34AB24 24 20.4—27.6 FCB34AC24 24 20.4—27.6 ...

Related keywords