rf2051 RF Micro Devices, rf2051 Datasheet - Page 11

no-image

rf2051

Manufacturer Part Number
rf2051
Description
High Performance Wideband Rf Synthesizer/vco With Integrated Rf Mixers
Manufacturer
RF Micro Devices
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RF2051
Manufacturer:
RFMD
Quantity:
5 000
Part Number:
rf2051SB
Manufacturer:
RFMD
Quantity:
5 000
Part Number:
rf2051SR
Manufacturer:
RFMD
Quantity:
5 000
Part Number:
rf2051TR13
Manufacturer:
MICRON
Quantity:
5 600
Part Number:
rf2051TR13
Manufacturer:
RFMD
Quantity:
20 000
Part Number:
rf2051TR7
Manufacturer:
RFMD
Quantity:
5 000
The RF2051 is a wideband RF frequency converter chip which includes a fractional-N phase-locked loop, a crystal oscillator cir-
cuit, a low noise VCO core, a LO signal multiplexer, two buffer circuits and two RF mixers. Synthesizer programming, device con-
figuration and control are achieved through a mixture of hardware and software controls. All on-chip registers are programmed
through a simple three-wire serial interface.
VCO
The VCO core in the RF2051 consists of three VCOs which, in conjunction with the integrated 2/4 LO divider, cover the LO
range from 300MHz to 2400MHz.
VCO 1, 2, and 3 are selected using the PLL1x0:P1_VCOSEL and PLL2x0:P2_VCOSEL control words. Each VCO has 128 overlap-
ping bands to achieve an acceptable VCO gain (20MHz/V nom) and hence a good phase noise performance across the whole
tuning range. The chip automatically selects the correct VCO band ("VCO coarse tuning") to generate the desired LO frequency
based on the values programmed into the PLL1 and PLL2 registers banks. For information on how to program the desired LO
frequency into the PLL1 and PLL2 banks refer to page 12.
The automatic VCO band selection is triggered every time the ENBL pin is taken high. Once the band has been selected the PLL
will lock onto the correct frequency. During the band selection process fixed capacitance elements are progressively connected
to the VCO resonant circuit until the VCO is oscillating at approximately the correct frequency. The output of this band selection
is made available in the RB1:CT_CAL read-back register. A value of 127 or 0 in this register indicates that the selection was
unsuccessful, this is usually due to the wrong VCO being selected so the user is trying to program a frequency that is outside of
the VCO operating range. A value between 1 and 126 indicates a successful calibration, the actual value being dependent on
the desired frequency as well as process variation for a particular device. The band selection takes approximately 1500 cycles
of the phase detector clock (about 50us with a 26MHz clock). The band select process will center the VCO tuning voltage at
about 1.2V, compensating for manufacturing tolerances and process variation as well as environmental factors including tem-
perature. For applications where the synthesizer is always on and the LO frequency is fixed, the synthesizer will maintain lock
over a +/-60°C temperature range. However it is recommended to re-initiate an automatic band selection for every 30 degrees
change in temperature in order to maintain optimal synthesizer performance. This assumes an active loop filter. If start-up
time is a critical parameter, and the user is always programming the same frequency for the PLL, the calibration result may be
read back from the RB1:CT_CAL register, and written to the PLL1x2:P1_CT_DEF or PLL2x2:P2_CT_DEF registers (depending on
desired PLL register bank). The calibration function must then be disabled by setting the PLL1x0:P1_CT_EN and/or
PLL2x0:P2_CT_EN control words to 0. For further information please refer to the RF205x Calibration User Guide.
The LO divide ratio is set by the PLL1x0:P1_LODIV and PLL2x0:P2_LODIV control words.
The LO is routed to mixer1, mixer2, or both depending on the state of the MODE pin and the value of CFG1:FULLD.
The current in the VCO core can be programmed using the PLL1x1:P1_VCOI or PLL2x1:P2_VCOI control words. This allows opti-
mization of VCO performance for a particular frequency. For applications where the required LO frequency is above 2GHz it is
recommended that the LO buffer current be increased by setting CFG5:LO1_I and CFG5:LO2_I to 1100 (hex value C).
Rev A1 DS090106
*The frequency of VCO3 is set by external inductors and can be varied by the user.
VCO
1
2
3
Tank Inductor
External
Internal
Internal
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
VCO Frequency Range
1200MHz to 1600MHz*
1800MHz to 2400MHz
1500MHz to 2100MHz
Detailed Description
900MHz to 1200MHz
750MHz to 1050MHz
600MHz to 800MHz
DIV 2
450MHz to 600MHz
375MHz to 525MHz
300MHz to 400MHz
DIV 4
RF2051