UPD62 NEC [NEC], UPD62 Datasheet - Page 12
UPD62
Manufacturer Part Number
UPD62
Description
4-BIT SINGLE-CHIP MICROCONTROLLER FOR INFRARED REMOTE CONTROL TRANSMISSION
Manufacturer
NEC [NEC]
Datasheet
1.UPD62.pdf
(64 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
UPD6211CX
Manufacturer:
TYCO
Quantity:
2 000
Part Number:
UPD6211CX
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD6222GS
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD6250C
Manufacturer:
NEC
Quantity:
20 000
Company:
Part Number:
UPD6252C
Manufacturer:
NEC
Quantity:
1 900
Company:
Part Number:
UPD6252C
Manufacturer:
Microsemi
Quantity:
1 900
Part Number:
UPD6252C
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD6252G
Manufacturer:
NEC
Quantity:
20 000
Company:
Part Number:
UPD6252GS-BA1-E
Manufacturer:
PERICOM
Quantity:
18 000
2.8 Arithmetic and Logic Unit (ALU): 4 Bits
manipulations with priority given to logical operations.
2.9 Flags
2.9.1 Status flag (F)
12
Operand Value of STTS Instruction
The arithmetic and logic unit (ALU), which refers to an arithmetic circuit consisting of 4 bits, executes simple
Pin and timer statuses can be checked by executing the STTS instruction to check the status flag.
The status flag is set (to 1) in the following cases.
• If the condition specified with the operand is met when the STTS instruction has been executed
• When STANDBY mode is canceled.
• When the cancelation condition is met at the point of executing the HALT instruction. (In this case, the system
Conversely, the status flag is cleared (to 0) in the following cases:
• If the condition specified with the operand is not met when the STTS instruction has been executed.
• When the status flag has been set (to 1), the HALT instruction executed, but the cancelation condition is not
b
0
1
3
is not placed in STANDBY mode.)
met at the point of executing the HALT instruction. (In this case, the system is not placed in STANDBY mode.)
Either of the combinations
of b
b
0
0
1
1
2
2
, b
1
, and b
Table 2-1. Conditions for Status Flag (F) to be Set by STTS Instruction
b
0
1
1
0
1
0
above.
b
0
1
0
1
0
High level is input to at least one of K
High level is input to at least one of K
High level is input to at least one of K
The down counter of the timer is 0.
High level is input to at least one of S
Data Sheet U14208EJ1V0DS00
[The following condition is added in addition to the above.]
Condition for Status Flag (F) to be Set
I
I
I
0
pins.
pins.
pins.
and S
1
pins.
PD62