UPD6124AGS NEC [NEC], UPD6124AGS Datasheet - Page 16

no-image

UPD6124AGS

Manufacturer Part Number
UPD6124AGS
Description
4-BIT SINGLE-CHIP MICROCONTROLLER FOR REMOTE CONTROL TRANSMISSION
Manufacturer
NEC [NEC]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD6124AGS-740
Manufacturer:
NEC
Quantity:
948
Part Number:
UPD6124AGS-A61-T1
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD6124AGS-B32
Manufacturer:
HIT
Quantity:
21
Part Number:
UPD6124AGS-B39
Manufacturer:
TEXAS
Quantity:
600
Part Number:
UPD6124AGS-B47
Manufacturer:
SHARP
Quantity:
800
Part Number:
UPD6124AGS-B47-E1
Manufacturer:
NEC
Quantity:
3 500
Part Number:
UPD6124AGS-B59
Manufacturer:
NEC
Quantity:
1 000
Part Number:
UPD6124AGS-B97
Manufacturer:
NEC
Quantity:
1 000
Part Number:
UPD6124AGS-E66
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD6124AGS-E87
Manufacturer:
NEC
Quantity:
1 000
Part Number:
UPD6124AGS-E95
Manufacturer:
NEC
Quantity:
20 000
16
15. AC PIN (ALL CLEAR PIN)
WATCHDOG TIMER FUNCTION
by connecting a 0.1 F capacitor across the AC pin and the V
Caution
Internal part of the CPU including the program counter can be reset by setting the AC pin to the low level.
A power-on reset function and a CR watchdog timer function, that can be controlled by program, can be realized
Charge mode
Charge-discharge
pattern
Discharge mode
When the watchdog timer function is not used, switch to charging mode by executing a NOP
instruction immediately before a HALT instruction at the beginning of the program. (Be sure to
connect the capacitor.)
0.1 F
0.1 F
V
V
thL
DD
V
V
DD
Charge start instruction
Discharge start instruction
Execute HALT instruction
immediately before NOP.
(Charge for 0.4 ms or more)
Discharge starts after the NOP
instruction execution.
(Discharge time is about 5 ms from V
SS
.
t
The pattern must be
controlled by the program,
in such a manner that
the C charge level will not
go below V
PD6124A, 6600A
thL
DD
.
to V
thL
)

Related parts for UPD6124AGS