UPD72042BGT NEC [NEC], UPD72042BGT Datasheet - Page 52

no-image

UPD72042BGT

Manufacturer Part Number
UPD72042BGT
Description
LSI DEVICE FOR Inter Equipment Bus (IEBus) PROTOCOL CONTROL
Manufacturer
NEC [NEC]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD72042BGT
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD72042BGT-E1
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD72042BGT-E1-A
Manufacturer:
MPS
Quantity:
2 001
Part Number:
UPD72042BGT-E1-A
Manufacturer:
NEC
Quantity:
20 000
52
1000
1001
1010
1011
Note See Note of Table 4-9.
SLRC
(c) Broadcast reception
Broadcast reception is performed when the broadcast bit is set to 0, and a communication frame with FFH
(general broadcast) or the local station group address specified in the slave address field is received.
Table 4-8 indicates the SLRC return codes for broadcast reception.
1. Meaning: Broadcast reception is started.
2. Occurrence condition:
3. Microcomputer processing: Three-byte data consisting of a master address, control bits, and data-
1. Meaning: The broadcast reception buffer is full.
2. Occurrence condition: This return code is issued when RBF becomes full during data reception as a
3. Microcomputer processing: If data consisting of one or more bytes is not read from RBF within the
1. Meaning: Broadcast reception was terminated normally.
2. Occurrence condition: This return code is issued when as much data as the amount specified in the
3. Microcomputer processing: Reception data can be read from RBF, and the number of bytes of
1. Meaning: Broadcast reception was aborted.
2. Occurrence condition: This return code is issued when reception is terminated prior to the reception
3. Microcomputer processing: Reception data can be read from RBF, and the number of bytes of
After the data-length field, 1000 is set in SLRC, and three-byte data consisting of a master address,
control bits, and data-length bits is set in RBF.
length bits can be read from RBF.
slave unit, preventing subsequent reception data from being set in RBF.
time below, broadcast reception is aborted.
• Reception data read time:
data-length field has been received normally in a communication frame. In this case, the SLRE flag of
the FLG register changes from 1 to 0.
broadcast reception data can be read from RDR2.
of as much data as the amount specified in the data-length field in a communication frame. In this case,
the SLRE flag of the FLG register changes from 1 to 0.
broadcast reception data can be read from RDR2.
1 A broadcast frame up to the data-length field was received from the master unit normally.
2 Once the control field has been received, RBF is ready for reception
Table 4-8 SLRC Return Codes for Broadcast Reception
Data Sheet S13990EJ3V0DS
Approx. 1570 s (mode 0)
Approx. 390 s (mode 1)
Description
Note
.
PD72042B

Related parts for UPD72042BGT