LTC2907 LINER [Linear Technology], LTC2907 Datasheet - Page 10

no-image

LTC2907

Manufacturer Part Number
LTC2907
Description
36V Nano-Current Two Input Voltage Monitor
Manufacturer
LINER [Linear Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC2907CDDB
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC2907CDDB#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC2907CTS8
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC2907CTS8#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC2907CTS8#TRPBF
Manufacturer:
LT
Quantity:
5 600
Part Number:
LTC2907IDDB
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC2907IDDB#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC2907ITS8
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC2907ITS8#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
LTC2960
APPLICATIONS INFORMATION
provide effective pull-down without excessively loading the
pull-up circuitry. A 100k resistor from output to ground is
satisfactory for most applications. When the status outputs
are high, power is dissipated in the pull-down resistors.
If V
are pulled to ground. The outputs are guaranteed to stay
low for V
tion. When V
similarly to an open-drain output with a pull-up resistor.
MANUAL RESET INPUT
When ADJ is above its reset threshold and the manual
reset input (MR) is pulled low, the RST output is forced
low. RST remains low for the selected reset timeout period
after the manual reset input is released and pulled high.
The manual reset input is pulled up internally through a
1μA current source to an internal bias voltage (see Elec-
trical Characteristics). If external leakage currents have
the ability to pull down the manual reset input below its
logic threshold, a pull-up resistor placed between V
10
IN
IN
Figure 4. LTC2960-3 (LTC2960-4) RST and OUT Outputs are
Configurable as Push-Pull or Open-Drain
+
+
CC
falls below the falling UVLO threshold, the outputs
0.4V
0.4V
CC
≥ 1.2V regardless of the output logic configura-
+
+
(b). OPEN-DRAIN CONFIGURATION
CC
(a). PUSH-PULL CONFIGURATION
< 1.2V, the active pull-up output behaves
LTC2960-3
LTC2960-3
DV
OUT
DV
OUT
CC
CC
2960 F04
1.6V TO 5.5V
6.3V MAX
CC
and MR is a solution to this issue. The MR input can be
pulled to 36V maximum and will not affect the internal
circuitry. Input MR is often pulled down through the use
of a pushbutton switch.
SELECTING THE RESET TIMEOUT PERIOD
Use the RT input (LTC2960-1/ LTC2960-2) to select between
two fixed reset timeout periods. Connect RT to ground for
a 15ms timeout. Connect RT to V
The reset timeout period occurs after the ADJ input is
driven above threshold and the MR input transitions above
its logic threshold. After the reset timeout period, the RST
output is allowed to pull up to a high state as shown in
Figure 5. The RT input is replaced by the DV
the LTC2960-3/LTC2960-4 options and the reset timeout
period defaults to 200ms.
EXTERNAL HYSTERESIS
The LTC2960 IN
or 5% referred to V
than the built-in native hysteresis. The application sche-
matic in Figure 6 adds one additional resistor (R6) to a
typical attenuator network. The procedure below is used
to determine a value for R6 to provide an increase over
the native hystereis. In this example, it is desired to double
the native hysteresis from 300mV to 600mV and achieve
a falling threshold of 6V.
Before including R6, the rising threshold (V
while the falling threshold (V
referred to V
V
HYST VA
ADJ
RST, RT = GND
RST, RT = V
(
Figure 5. Selectable Reset Timeout Period
)
A
= V
CC
is calculated from:
+
comparator hysteresis is 20mV (V
PHYS
TH
15ms
. Certain applications require more
⎝ ⎜
1+
R4
R5
F
200ms
) is 5.993V. The hysteresis
⎠ ⎟
=20mV •15 = 300mV
CC
for a 200ms timeout.
2960 F05
R
) is 6.293V
CC
input in
+
HYS
2960f
),