ICS1893 Integrated Circuit Systems, ICS1893 Datasheet - Page 74

no-image

ICS1893

Manufacturer Part Number
ICS1893
Description
3.3-V 10Base-T/100Base-TX Integrated PHYceiver
Manufacturer
Integrated Circuit Systems
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ICS1893AF
Manufacturer:
ICS
Quantity:
20 000
Company:
Part Number:
ICS1893AF
Quantity:
30
Part Number:
ICS1893AFILF
Manufacturer:
IDT
Quantity:
110
Part Number:
ICS1893AFLF
Manufacturer:
ICS
Quantity:
20 000
Part Number:
ICS1893AFT
Manufacturer:
IDT
Quantity:
8 000
Part Number:
ICS1893BF
Manufacturer:
ICS
Quantity:
20 000
Part Number:
ICS1893BFI
Manufacturer:
OKI
Quantity:
1 934
Part Number:
ICS1893BFILF
Manufacturer:
ICS
Quantity:
20 000
Part Number:
ICS1893BFLF
Manufacturer:
ICS
Quantity:
409
Part Number:
ICS1893BFLF
Manufacturer:
ICS
Quantity:
20 000
Part Number:
ICS1893BFLFT
Manufacturer:
IDT
Quantity:
8 000
Part Number:
ICS1893BKILFT
Manufacturer:
IDT
Quantity:
5 000
Part Number:
ICS1893BY-10
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
ICS1893BY-10LF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
ICS1893BY-10LFT
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
8.5 Register 3: PHY Identifier Register
8.5.1 OUI bits 19-24 (bits 3.15:10)
ICS1893 Rev C 6/6/00
Table 8-9
that are part of a set defined by the ISO/IEC specification. This register stores the following:
All the bits in the two PHY Identifier Registers are Command Override Write bits. An STA can read them at
any time without condition. However, An STA can modify these register bits only when the Command
Register Override bit (bit 16.15) is enabled with a logic one.
Note:
Table 8-9.
The most-significant 6 bits of register 3 (that is, bits 3.15:10) include OUI bits 19 through 24. OUI bit 19 is
stored in bit 3.15, while OUI bit 24 is stored in bit 3.10.
3.15
3.14
3.13
3.12
3.11
3.10
Part of the OUI [see the text in
Manufacturer’ s PHY Model Number
Manufacturer’ s PHY Revision Number
Bit
3.9
3.8
3.7
3.6
3.5
3.4
3.3
3.2
3.1
3.0
ICS1893 Data Sheet - Release
For an explanation of acronyms used in
OUI bit 19 | s
OUI bit 20 | t
OUI bit 21 | u
OUI bit 22 | v
OUI bit 23 | w
OUI bit 24 | x
Manufacturer’ s Model Number bit 5
Manufacturer’ s Model Number bit 4
Manufacturer’ s Model Number bit 3
Manufacturer’ s Model Number bit 2
Manufacturer’ s Model Number bit 1
Manufacturer’ s Model Number bit 0
Revision Number bit 3
Revision Number bit 2
Revision Number bit 1
Revision Number bit 0
lists the bits for PHY Identifier Register (Register 3), which is one of two PHY Identifier Registers
PHY Identifier Register (Register 3 [0x03])
Definition
Copyright © 2000, Integrated Circuit Systems, Inc.
All rights reserved.
Section 8.4, “ Register 2: PHY Identifier Register”
When Bit = 0 When Bit = 1
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
74
Table
8-5, see
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Chapter 1, “ Abbreviations and Acronyms”
Access
Chapter 8 Management Register Set
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
CW
Function
Special
]
Default
1
1
1
1
0
1
0
0
0
1
0
0
0
0
0
1
June, 2000
Hex
F
4
4
1
.

Related parts for ICS1893