SAA7371GP Philips Semiconductors, SAA7371GP Datasheet - Page 27

no-image

SAA7371GP

Manufacturer Part Number
SAA7371GP
Description
Digital servo processor and Compact Disc decoder CD7
Manufacturer
Philips Semiconductors
Datasheet
Philips Semiconductors
The sledge is continuously controlled, or provided with
step pulses to reduce power consumption using the
filtered value of the radial PID output. Alternatively, the
microcontroller can read the average voltage on the radial
actuator and provide the sledge with step pulses to reduce
power consumption. Filter coefficients of the continuous
sledge control can be preset by the user.
7.14.4.4
The access procedure is divided into two different modes
(see Table 11), depending on the requested jump size.
Table 11 Access modes
Note
1. Microcontroller presettable.
The access procedure makes use of a track counting
mechanism, a velocity signal based on a fixed number of
tracks passed within a fixed time interval, a velocity
setpoint calculated from the number of tracks to go and a
user programmable parameter indicating the maximum
sledge performance.
If the number of tracks remaining is greater than the
brake_distance then the sledge jump mode should be
activated or, the actuator jump should be performed.
The requested jump size together with the required sledge
breaking distance at maximum access speed defines the
brake_distance value.
During the actuator jump mode, velocity control with a PI
controller is used for the actuator. The sledge is then
continuously controlled using the filtered value of the radial
PID output. All filter parameters (for actuator and sledge)
are user programmable.
In the sledge jump mode maximum power (user
programmable) is applied to the sledge in the correct
direction while the actuator becomes idle (the contents of
the actuator integrator leaks to zero just after the sledge
jump mode is initiated). The actuator can be electronically
damped during sledge jump. The gain of the damping loop
is controlled via the hold_mult parameter.
1998 Jul 06
Actuator jump
Sledge jump
Digital servo processor and
Compact Disc decoder (CD7)
ACCESS
TYPE
Access
brake_distance - 32768
1 - brake_distance
JUMP SIZE
(1)
decreasing
maximum
ACCESS
power to
sledge
SPEED
velocity
(1)
27
Fast track jumping circuitry can be enabled/disabled via
the xtra_preset parameter.
7.14.4.5
The loop gain of the radial control loop can be corrected
automatically to eliminate tolerances in the radial loop.
This gain control injects a signal into the loop which is used
to correct the loop gain. Since this decreases the optimum
performance, the gain control should only be activated for
a short time (for example, when starting a new disc).
This gain control differs from the level initialization.
The level initialization should be performed first.
The disadvantage of using the level initialization without
the gain control is that only tolerances from the front-end
are reduced.
7.14.5
The track position signal (TPI) is a flag which is used to
indicate whether the radial spot is positioned on the track,
with a margin of 1/4 of the track-pitch. In combination with
the radial polarity flag (RP) the relative spot position over
the tracks can be determined. These signals are, however,
afflicted with some uncertainties caused by;
In order to determine the spot position with sufficient
accuracy, extra conditions are necessary to generate a
track loss signal (TL) as well as an off-track counter value.
These extra conditions influence the maximum speed and
this implies that, internally, one of the following three
counting states is selected;
1. Protected state: used in normal play situations. A good
2. Slow counting state: used in low velocity track jump
3. Fast counting state: used in high velocity track jump
Disc defects such as scratches and fingerprints
The HF information on the disc, which is considered as
noise by the detector signals.
protection against false detection caused by disc
defects is important in this state.
situations. In this state a fast response is important
rather than the protection against disc defects (if the
phase relationship between TL and RP of 1/2 radians
is affected too much, the direction cannot be
determined accurately any more).
situations. Highest obtainable velocity is the most
important feature in this state.
O
FF
Radial automatic gain control loop
-
TRACK COUNTING
Product specification
SAA7371