XC3S200 XILINX [Xilinx, Inc], XC3S200 Datasheet - Page 12

no-image

XC3S200

Manufacturer Part Number
XC3S200
Description
XC17V00 Series Configuration PROMs
Manufacturer
XILINX [Xilinx, Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC3S200
Manufacturer:
XILINX
0
Part Number:
XC3S200 4PQG208C0974
Manufacturer:
XILINX
0
Part Number:
XC3S200-1TQ144I
Manufacturer:
XILINX
0
Part Number:
XC3S200-2FT256GI
Manufacturer:
XILINX
0
Part Number:
XC3S200-2TQ144C
Manufacturer:
XILINX
0
Part Number:
XC3S200-4FT256C
Manufacturer:
XIL
Quantity:
82
Part Number:
XC3S200-4FT256C
Manufacturer:
XILINX/赛灵思
Quantity:
20 000
Part Number:
XC3S200-4FT256I
Manufacturer:
XILINX/赛灵思
Quantity:
20 000
Part Number:
XC3S200-4FT256I
Quantity:
80
AC Characteristics over Operating Condition for XC17V16 and XC17V08
X-Ref Target - Figure 5
DS073 (v1.12) November 13, 2008
Product Specification
Notes:
1.
2.
3.
4.
5.
6.
7.
RESET/OE
Symbol
T
T
T
T
T
T
T
T
SBUSY
HBUSY
T
T
T
T
T
T
CYC
HCE
HOE
CEH
CAC
SCE
AC test load = 50 pF.
When BUSY = 0.
Float delays are measured with 5 pF AC loads. Transition is measured at ±200 mV from steady state active levels.
Guaranteed by design, not tested.
All AC parameters are measured with V
If T
If T
OE
OH
HC
CE
DF
LC
BUSY
CEH
HOE
DATA
CLK
CE
(2)
(1)
High, 2 μs, T
High, 2 μs, T
OE to data delay
CE to data delay
CLK to data delay
CE or OE to data float delay
Data hold from CE, OE, or CLK
Clock periods
CLK Low time
CLK High time
CE setup time to CLK (to guarantee proper counting)
CE hold time to CLK (to guarantee proper counting)
OE hold time (guarantees counters are reset)
BUSY setup time
BUSY hold time
CE High time (guarantees counters are reset)
R
Note:
1 The XC17V00 RESET/OE input polarity is programmable. The RESET/OE input is shown in the timing diagram with active-high RESET polarity.
2. If BUSY is inactive (Low) during a rising CLK edge, then new DATA appears at time T
Timing specifications are identical for both polarity settings.
during a rising CLK edge, then there is no corresponding change to DATA.
CE
OE
(4)
(4)
= 2 μs.
= 2 μs.
T CE
(2)
T OE
T SCE
(3,4)
Description
IL
(4)
= 0.0V and V
T LC
T CAC
IH
T HC
T SBUSY
= 3.0V.
www.xilinx.com
CAC
after the rising CLK edge. If BUSY is active (High)
T HBUSY
XC17V00 Series Configuration PROMs
Min
50
25
25
25
25
20
0
0
5
5
T OH
T OH
T SCE
T CYC
Max
15
20
20
35
T DF
T HOE
TCEH
Units
DS073_05_031606
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
T HCE
12