XC3042 XILINX [Xilinx, Inc], XC3042 Datasheet - Page 7

no-image

XC3042

Manufacturer Part Number
XC3042
Description
Logic Cell Array Families
Manufacturer
XILINX [Xilinx, Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC3042
Manufacturer:
XILINX
0
Part Number:
XC3042 70PC84C
Manufacturer:
XILINX
0
Part Number:
XC3042 PC84 100C
Manufacturer:
XILINX
Quantity:
96
Part Number:
XC3042 PC84 100C
Manufacturer:
XILINX
0
Part Number:
XC3042 PC84 70C
Manufacturer:
XILINX
Quantity:
13
Part Number:
XC3042 PC84 70C
Quantity:
15
Part Number:
XC3042-100
Quantity:
12
Part Number:
XC3042-100
Manufacturer:
XILINX
0
Part Number:
XC3042-100CB100M
Manufacturer:
XILINX
0
Part Number:
XC3042-100CQ100C
Manufacturer:
XILINX
Quantity:
6
Part Number:
XC3042-100PC84
Manufacturer:
XILINX/赛灵思
Quantity:
20 000
Configurable Logic Block
The array of CLBs provides the functional elements from
which the user’s logic is constructed. The logic blocks are
arranged in a matrix within the perimeter of IOBs. The
XC3020 has 64 such blocks arranged in 8 rows and 8
columns. The XACT development system is used to com-
pile the configuration data which is to be loaded into the
internal configuration memory to define the operation and
interconnection of each block. User definition of CLBs and
their interconnecting networks may be done by automatic
translation from a schematic-capture logic diagram or
optionally by installing library or user macros.
Figure 4. Configurable Logic Block. Each CLB includes a combinatorial logic section, two flip-flops and a program
memory controlled multiplexer selection of function. It has. five logic variable inputs A, B, C, D, and E
ENABLE CLOCK
VARIABLES
DATA IN
DIRECT
CLOCK
RESET
LOGIC
DI
A
B
C
D
E
EC
K
RD
QX
QY
COMBINATORIAL
(GLOBAL RESET)
FUNCTION
1 (ENABLE)
0 (INHIBIT)
G
F
a direct data in DI
an enable clock EC
a clock (invertible) K
an asynchronous direct RESET RD
two outputs X and Y
2-109
F
DIN
G
F
DIN
G
Each CLB has a combinatorial logic section, two flip-flops,
and an internal control section. See Figure 4. There are:
five logic inputs (A, B, C, D and E); a common clock input
(K); an asynchronous direct RESET input (RD); and an
enable clock (EC). All may be driven from the interconnect
resources adjacent to the blocks. Each CLB also has two
outputs (X and Y) which may drive interconnect networks.
Data input for either flip-flop within a CLB is supplied from
the function F or G outputs of the combinatorial logic, or the
block input, DI. Both flip-flops in each CLB share the
MUX
MUX
0
1
0
1
D
D
RD
RD
Q
Q
QX
F
G
QY
CLB OUTPUTS
X
Y
X3032