CY8C20111_12 CYPRESS [Cypress Semiconductor], CY8C20111_12 Datasheet - Page 35

no-image

CY8C20111_12

Manufacturer Part Number
CY8C20111_12
Description
Manufacturer
CYPRESS [Cypress Semiconductor]
Datasheet
Appendix
Examples of Frequently Used I
Document Number: 001-53516 Rev. *H
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Note
SI. No.
12. The ‘W’ indicates the write transfer and the next byte of data represents the 7-bit I2C address. The I2C address is assumed to be ‘0’ in the above examples.
Similarly ‘R’ indicates the read transfer followed by 7-bit address and data byte read operations.
Enter into setup mode
Enter into normal mode
Load factory defaults to RAM
registers
Do a software reset
Save current configuration to
flash
Load factory defaults to RAM
registers and save as user config-
uration
Disable combinational logic
output to DIG0
Disable combinational logic
output to DIG1
Clearing (logic 0) the both DIG0
and DIG1 outputs
Setting (logic 1) the DIG0 and
clearing (Logic 0) the DIG1
outputs
Clearing (logic 0) the DIG0 and
Setting (Logic 1) the DIG1
outputs
Setting (logic 1) the both DIG0
and DIG1 outputs
Change CapSense clock to
IMO/2
Change value of IDAC0 to ‘x’h
Change value of IDAC1 to ‘y’h
Change value of IDAC0 and
IDAC1 to ‘x’h and ‘y’h
Change the value FT0 to ‘x’h
Change the value FT1 to ‘y’h
Change the value FT0 and FT1 to
‘x’h and ‘y’h
Change noise threshold to ‘x’h
Read CapSense button CS0
scan results
Read CapSense button status
register
Requirement
2
C Commands
W 00 A0 08
W 00 A0 07
W 00 A0 02
W 00 A0 08
W 00 A0 06
W 00 A0 01
W 00 A0 08
W 00 A0 02
W 00 A0 01
W 00 A0 06
W 00 1C 00
W 00 21 00
W 00 04 00
W 00 04 01
W 00 04 02
W 00 04 03
W 00 A0 08
W 00 51 20
W 00 A0 07
W 00 70 x
W 00 71 y
W 00 70 x y
W 00 66 x
W 00 67 y
W 00 66 x y
W 00 4E x
W 00 81 81
W 00 82
R 00 RD RD RD RD
RD RD
W 00 88
R 00 RD
I
2
C Commands
[12]
; Enter into setup mode
; Do software reset
; Enter into setup mode
; Load factory defaults to SRAM
; Save the configuration to flash. Wait for time specified in
CapSense Express Commands on page
; Do software reset
Combinational logic output on DIG0 and DIG1 should be
disabled before dong this operation (SL# 7 and 8)
; Enter into setup mode
; CapSense clock is set as IMO/2
; Enter into normal mode
‘x’ represents new value of IDAC register
‘y’ represents new value of IDAC register
‘x’ and ‘y’ represents new value of IDAC register
‘x’ represents new value of FT register
‘y’ represents new value of FT register
‘x’ and ‘y’ represents new value of FT registers
; Select CapSense button for reading scan result
; Set the read point to 82h
; Consecutive 6 reads gets baseline, difference count and raw
count (all two byte each)
; Set the read pointer to 88
; Reading a byte gets status CapSense inputs
CY8C20111, CY8C20121
Comments
11.
Page 35 of 44

Related parts for CY8C20111_12