LUPA-1300 CYPRESS [Cypress Semiconductor], LUPA-1300 Datasheet - Page 33

no-image

LUPA-1300

Manufacturer Part Number
LUPA-1300
Description
1.3 M Pixel High Speed CMOS Image Sensor
Manufacturer
CYPRESS [Cypress Semiconductor]
Datasheet
4.3 Timing of the Serial Parallel Interface (SPI)
The serial parallel interface is used to upload the x- and y-address into the x- and y-
address registers. This address is the starting point of the window of interest and is
uploaded in the shift register by means of the corresponding synchronization pulse.
The elementary unit cell of the serial to parallel interface is shown in Figure 19. 16 of
these cells are connected in parallel, having a common Load_addr and Clock_spi
form the entire uploadable address block. The uploaded addresses are applied to the
sensor on the rising edge of signal Load_addr.
The Y-address has to be applied first and the X-address last. With respect to the
timing in figure 19, A1 corresponds with the least significant bit of the Y-address
(Y0) and A16 corresponds with the most significant bit of the X-address (X5). The
Y-address is a 10 bit and the X-address is a 6-bit address register
Cypress Semiconductor Corporation
Contact info@Fillfactory.com
Load_address
Address_in
Clock_spi
LUPA-1300
Datasheet
Unity Cell
D
D
C
C
To address registers
Q
Q
Figure 19: Schematic of the SPI interface
Document # : 38-05711 Rev.**( Revision 3.1)
Address_out
3901 North First Street
Address
Clock_spi
Clock_spi
Load_addr
address
Load_addr
San Jose, CA 95134
A1
16 outputs to sensor : 6 x-address
bits and 10 y-address bits
Entire uploadable address block
A2
.
A3
Page 33 of 48
408-943-2600
A16
command
applied to
sensor