Features and Benefits Relative Integrated Pressure sensor Less than ±1% error range overall Programmable through the connector (3 pins) Trimmable offset and sensitivity On-Chip Signal Conditioning Output proportional to the applied pressure Ratiometric output Rail-to-rail output Diagnostics of broken supply ...
Page 2
FUNCTIONAL DIAGRAM...................................................................................................................... 1 2. DESCRIPTION....................................................................................................................................... 2 3. ABSOLUTE MAXIMUM RATINGS ....................................................................................................... 3 4. MLX90257 ELECTRICAL SPECIFICATIONS ...................................................................................... 3 5. GENERAL DESCRIPTION .................................................................................................................... 4 6. UNIQUE FEATURES ............................................................................................................................. 4 7. PERFORMANCE GRAPHS................................................................................................................... 5 8. APPLICATION INFORMATION ............................................................................................................ 6 9. DIE ...
Page 3
Absolute Maximum Ratings Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute- maximum-rated conditions for extended periods may affect device reliability. 4. MLX90257 Electrical Specifications DC Operating Parameters T = -40 A Parameter OPERATIONAL FEATURES DIAGNOSTIC ...
Page 4
General Description This chip integrates a pressure sensor and the associated signal conditioning on the same die. The supply voltage V directly supplies the pressure sensor chopped instrumentation stage amplifies the differential output signal of the sensor. ...
Page 5
Performance Graphs The graphs below show measured output voltages taken at 20 differential pressure points (0 mBar to 2000 mBar between pressure ports ambient temperature points (-50 to 150 Celsius) and with Vdd set to 4.5 V, ...
Page 6
Error versus Pressure with 50..150 C 1.5 1 0.5 0 -0.5 -1 -1.5 0 250 500 4.5V and 5.5V Ratiometricity Error versus Pressure with 50..150 C 0.5 0.4 0.3 0.2 0.1 0 -0.1 -0.2 ...
Page 7
Die dimension and pad coordinates Available upon request. 10. Calibration and Programming Procedure Programming in Temporary Memory The programming is done through the connector: only the application pins (supply, ground and output) need to be used. The programming can ...
Page 8
In order to check zapping, one can program Test Mode 22 = 10110b. Also 1 bit of the temporary memory should be ‘1’. If the zap cell – corresponding to the place of the ‘1’ in the temporary memory – ...