AT26DF321-S3U ATMEL [ATMEL Corporation], AT26DF321-S3U Datasheet - Page 22

no-image

AT26DF321-S3U

Manufacturer Part Number
AT26DF321-S3U
Description
32-megabit 2.7-volt Only Serial Firmware DataFlash Memory
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT26DF321-S3U
Manufacturer:
TI
Quantity:
78
Part Number:
AT26DF321-S3U
Manufacturer:
ATMEL
Quantity:
20 000
11. Other Commands and Functions
11.1
Table 11-1.
22
Byte No.
Read Manufacturer and Device ID
AT26DF321 [Preliminary]
1
2
3
4
Manufacturer and Device ID Information
Data Type
Manufacturer ID
Device ID (Part 1)
Device ID (Part 2)
Extended Device Information String Length
Table 10-2.
Figure 10-2. Write Status Register
Identification information can be read from the device to enable systems to electronically query
and identify the device while it is in system. The identification method and the command opcode
comply with the JEDEC standard for “Manufacturer and Device ID Read Methodology for SPI
Compatible Serial Interface Memory Devices”. The type of information that can be read from the
device includes the JEDEC defined Manufacturer ID, the vendor specific Device ID, and the ven-
dor specific Extended Device Information.
To read the identification information, the CS pin must first be asserted and the opcode of 9Fh
must be clocked into the device. After the opcode has been clocked in, the device will begin out-
putting the identification data on the SO pin during the subsequent clock cycles. The first byte
that will be output will be the Manufacturer ID followed by two bytes of Device ID information.
The fourth byte output will be the Extended Device Information String Length, which will be 00h
indicating that no Extended Device Information follows. After the Extended Device Information
String Length byte is output, the SO pin will go into a high-impedance state; therefore, additional
clock cycles will have no affect on the SO pin and no data will be output. As indicated in the
JEDEC standard, reading the Extended Device Information String Length and any subsequent
data is optional.
Deasserting the CS pin will terminate the Manufacturer and Device ID read operation and put
the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not
require that a full byte of data be read.
SPRL
Bit 7
Write Status Register Format
SCK
SO
CS
Bit 6
SI
X
Bit 5
HIGH-IMPEDANCE
MSB
0
0
0
1
0
2
OPCODE
Global Protect/Unprotect
0
3
Bit 4
0
4
0
5
0
6
1
7
MSB
D
8
Bit 3
STATUS REGISTER IN
X
9
D
10 11
D
D
12
Bit 2
D
13
X
14 15
X
Bit 1
X
3633C–DFLASH–08/06
Value
1Fh
47h
00h
00h
Bit 0
X

Related parts for AT26DF321-S3U