AT29LV020-20 ATMEL [ATMEL Corporation], AT29LV020-20 Datasheet - Page 2

no-image

AT29LV020-20

Manufacturer Part Number
AT29LV020-20
Description
2 Megabit 256K x 8 3-volt Only CMOS Flash Memory
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT29LV020-20JC
Manufacturer:
ATMEL
Quantity:
3 465
Part Number:
AT29LV020-20JC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT29LV020-20JC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT29LV020-20JI
Manufacturer:
ATMEL
Quantity:
3 338
Part Number:
AT29LV020-20JI
Manufacturer:
ATMEL
Quantity:
3 464
Part Number:
AT29LV020-20JI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT29LV020-20JI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Company:
Part Number:
AT29LV020-20JI
Quantity:
2 500
Part Number:
AT29LV020-20JU
Manufacturer:
ATMEL
Quantity:
3 463
Part Number:
AT29LV020-20TC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT29LV020-20TI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT29LV020-20TU
Manufacturer:
ATMEL
Quantity:
6 500
Part Number:
AT29LV020-20TU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Description (Continued)
EPROM. Reprogramming the AT29LV020 is performed
on a sector basis; 256-bytes of data are loaded into the
device and then simultaneously programmed.
During a reprogram cycle, the address locations and 256-
bytes of data are captured at microprocessor speed and
internally latched, freeing the address and data bus for
Block Diagram
Device Operation
READ:
When CE and OE are low and WE is high, the data stored
at the memory location determined by the address pins is
asserted on the outputs. The outputs are put in the high
impedance state whenever CE or OE is high. This dual-
line control gives designers flexibility in preventing bus
contention.
SOFTWARE DATA PROTECTION PROGRAMMING:
The AT29LV020 has 1024 individual sectors, each 256-
bytes. Using the software data protection feature, byte
loads are used to enter the 256-bytes of a sector to be
programmed. The AT29LV020 can only be programmed
or reprogrammed using the software data protection fea-
ture. The device is programmed on a sector basis. If a byte
of data within the sector is to be changed, data for the en-
tire 256-byte sector must be loaded into the device. The
AT29LV020 automatically does a sector erase prior to
loading the data into the sector. An erase command is not
required.
Software data protection protects the device from inadver-
tent programming. A series of three program commands
to specific addresses with specific data must be presented
to the device before programming may occur. The same
three program commands must begin each program op-
eration. All software program commands must obey the
sector program timing specifications. Power transitions
will not reset the software data protection feature, however
the software feature will guard against inadvertent pro-
gram cycles during power transitions.
Any attempt to write to the device without the 3-byte com-
mand sequence will start the internal write timers. No data
4-74
The AT29LV020 is accessed like an EPROM.
AT29LV020
other operations. Following the initiation of a program cy-
cle, the device will automatically erase the sector and then
program the latched data using an internal control timer.
The end of a program cycle can be detected by DATA poll-
ing of I/O7. Once the end of a program cycle has been
detected, a new access for a read or program can begin.
will be written to the device; however, for the duration of
t
After the software data protection’s 3-byte command code
is given, a byte load is performed by applying a low pulse
on the WE or CE input with CE or WE low (respectively)
and OE high. The address is latched on the falling edge of
CE or WE, whichever occurs last. The data is latched by
the first rising edge of CE or WE.
The 256-bytes of data must be loaded into each sector.
Any byte that is not loaded during the programming of its
sector will be erased to read FFH. Once the bytes of a
sector are loaded into the device, they are simultaneously
programmed during the internal programming period. Af-
ter the first data byte has been loaded into the device, suc-
cessive bytes are entered in the same manner. Each new
byte to be programmed must have its high to low transition
on WE (or CE) within 150 s of the low to high transition of
WE (or CE) of the preceding byte. If a high to low transition
is not detected within 150 s of the last low to high transi-
tion, the load period will end and the internal programming
period will start. A8 to A17 specify the sector address. The
sector address must be valid during each high to low tran-
sition of WE (or CE). A0 to A7 specify the byte address
within the sector. The bytes may be loaded in any order;
sequential loading is not required. Once a programming
operation has been initiated, and for the duration of t
read operation will effectively be a polling operation.
WC
, a read operation will effectively be a polling operation.
(continued)
WC
, a

Related parts for AT29LV020-20