AT29LV020-20 ATMEL [ATMEL Corporation], AT29LV020-20 Datasheet - Page 7

no-image

AT29LV020-20

Manufacturer Part Number
AT29LV020-20
Description
2 Megabit 256K x 8 3-volt Only CMOS Flash Memory
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT29LV020-20JC
Manufacturer:
ATMEL
Quantity:
3 465
Part Number:
AT29LV020-20JC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT29LV020-20JC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT29LV020-20JI
Manufacturer:
ATMEL
Quantity:
3 338
Part Number:
AT29LV020-20JI
Manufacturer:
ATMEL
Quantity:
3 464
Part Number:
AT29LV020-20JI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT29LV020-20JI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Company:
Part Number:
AT29LV020-20JI
Quantity:
2 500
Part Number:
AT29LV020-20JU
Manufacturer:
ATMEL
Quantity:
3 463
Part Number:
AT29LV020-20TC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT29LV020-20TI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT29LV020-20TU
Manufacturer:
ATMEL
Quantity:
6 500
Part Number:
AT29LV020-20TU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Program Cycle Characteristics
Software Protected Program Waveform
Notes: 1. OE must be high when WE and CE are both low.
Programming Algorithm
Symbol
t
t
t
t
t
t
t
t
WC
AS
AH
DS
DH
WP
BLC
WPH
2. A8 through A17 must specify the sector address
during each high to low transition of WE (or CE)
after the software code has been entered.
SECTOR (256 BYTES)
ADDRESS 2AAA
ADDRESS 5555
ADDRESS 5555
LOAD DATA AA
LOAD DATA 55
LOAD DATA A0
LOAD DATA
Parameter
Write Cycle Time
Address Set-up Time
Address Hold Time
Data Set-up Time
Data Hold Time
Write Pulse Width
Byte Load Cycle Time
Write Pulse Width High
TO
TO
TO
TO
(3)
WRITES ENABLED
ENTER DATA
PROTECT STATE
(1)
(2)
Min
100
100
200
200
10
10
Notes for software program code:
1. Data Format: I/O7 - I/O0 (Hex);
2. Data Protect state will be re-activated at end of program cycle.
3. 256-bytes of data
3. All bytes that are not loaded within the sector being
Address Format: A14 - A0 (Hex).
programmed will be indeterminate.
MUST BE
Max
150
20
AT29LV020
loaded.
Units
ms
ns
ns
ns
ns
ns
ns
s
4-79

Related parts for AT29LV020-20