BD6086GU
3. I/V conversion
4. AD conversion
Auto Luminous control operates as Low Gain as High Gain at the time of "10" when GAIN (1:0) is "01."
(*1) Please set the relative ratio of resistance. In this case, be careful of the difference in brightness conversion in High Gain mode and Low Gain mode.
・ SBIAS output equips with intermittent operation mode and always ON-mode. Pull-down [ SBIAS and a SSENS terminal ]
・ Detection of Ambient light information is periodically performed for low-power realization.
・ The current which turns off SBIAS and ADC and is generated by the sensor is controlled except the time of Ambient light
Operation mode
Gain switching function is built in to extend the dynamic range.
Effective / non-effect of automatic gain control are register setup.
GC1 and the output logic of GC2 can be set up by the manual
at the time of automatic gain control invalid.
measurement.
inside at the time of OFF.
GC1 output
GC2 output
S B IA S
Bit : GAIN (1:0)
Bit : ADCYC(1:0)
Bit : SBIASON
Application
Application
GAIN(1:0)
Gain state
A D C M ovem ent
A LC E N
G C 1, G C 2
A D C C ycle
A M B (3:0)
Sensor
circuit
O utput
T
T
w ait= 64m s(typ)
A M B = 80.4m s(typ)
Automatic
Automatic
H
L
ex1
VCC
BH1600
GND
00
(BH1600FVC and connection)
IOUT
GC1
GC2
H
L
T
A D C YC (1:0)
A D = 16.4m s(typ)
High
01
H
L
A M B (3:0)
SBIAS
SSENS
GC1
GC2
SGND
Manual
G C 1, G C 2=00
W hen S B IA S O N =1
Low
10
H
L
67/80
Automatic
Automatic
H
L
00
Resistance is a relative valu
H
L
ex3
High
01
H
L
SBIAS
SSENS
GC1
GC2
SGND
Manual
Low
A D start signal
00
H
L
No Gain
control
16 tim es m easurem ent
Ambient light
T
A D one= 1.024m s(typ)
Fixation
Gain control
ex3
Technical Note
01
2011.04 - Rev.A