DETAILED DEVICE DESCRIPTION
The X9523 combines two Intersil Digitally Controlled
Potentiometer (DCP) devices, V1/Vcc power-on reset
control, V1/Vcc low voltage reset control, and two sup-
plementary voltage monitors in one package. These
functions are suited to the control, support, and monitor-
ing of various system parameters in fiber optic modules.
The combination of the X9523 fucntionality lowers sys-
tem cost, increases reliability, and reduces board space
requirements using Intersil’s unique XBGA™ packaging.
Two high resolution DCPs allow for the “set-and-forget”
adjustment of Laser Driver IC parameters such as Laser
Diode Bias and Modulation Currents.
Applying voltage to V
circuit which allows the V1RO output to go HIGH, until
the supply the supply voltage stabilizes for a period of
time (selectable via software). The V1RO output then
goes LOW. The Low Voltage Reset circuitry allows the
V1RO output to go HIGH when V
mum V
PIN CONFIGURATION
V3RO
SDA
R
SCL
R
V
CC
R
MR
WP
W2
V3
H2
SS
L2
trip point. V1RO remains HIGH until V
20 Pin TSSOP
10
1
2
3
4
5
6
7
8
9
CC
20
19
18
17
16
15
14
13
12
11
activates the Power-on Reset
2
V1 / Vcc
V1RO
V2RO
V2
NC
NC
NC
R
R
R
H1
W1
L1
CC
NOT TO SCALE
falls below the mini-
A
B
C
D
E
CC
V2RO
X9523
R
V
NC
V2
SS
H1
Top View – Bumps Down
1
V1 / Vcc
V1RO
R
returns to proper operating level. A Manual Reset (MR)
input allows the user to externally trigger the V1RO out-
put (HIGH).
Two supplementary Voltage Monitor circuits continuously
compare their inputs to individual trip voltages. If an input
voltage exceeds it’s associated trip level, a hardware out-
put (V3RO, V2RO) are allowed to go HIGH. If the input
voltage becomes lower than it’s associated trip level, the
corresponding output is driven LOW. A corresponding
binary representation of the two monitor circuit outputs
(V2RO and V3RO) are also stored in latched, volatile
(CONSTAT) register bits. The status of these two moni-
tor outputs can be read out via the 2-wire serial port.
Intersil’s unique circuits allow for all internal trip volt-
ages to be individually programmed with high accu-
racy. This gives the designer great flexibility in
changing system parameters, either at the time of
manufacture, or in the field.
The device features a 2-Wire interface and software
protocol allowing operation on an I
serial bus.
NC
NC
2
W1
XBGA
V3RO
R
R
R
MR
3
W2
H2
L1
SDA
SCL
R
WP
V3
4
L2
2
C™ compatible
March 10, 2005
FN8209.0

Related parts for X9523