M30280F6HP RENESAS [Renesas Technology Corp], M30280F6HP Datasheet - Page 335

no-image

M30280F6HP

Manufacturer Part Number
M30280F6HP
Description
16-BIT SINGLE-CHIP MICROCOMPUTER M16C FAMILY / M16C/Tiny SERIES
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M30280F6HP
Manufacturer:
RENESAS
Quantity:
5 000
Company:
Part Number:
M30280F6HP
Quantity:
12 590
Part Number:
M30280F6HP D5A
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
M30280F6HP D5A
Quantity:
12 474
Part Number:
M30280F6HP#D5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M30280F6HP#D5
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
M30280F6HP#U3B
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
M30280F6HP#U3B
Manufacturer:
Renesas
Quantity:
201
Part Number:
M30280F6HP#U3B
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M30280F6HP#U3BU3H
Quantity:
20
Part Number:
M30280F6HP#U5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M30280F6HP#U5
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
M30280F6HP#U5B
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M30280F6HP#U5B
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
M30280F6HP#U7
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
M30280F6HP#U7B
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
M30280F6HP#U9B
Manufacturer:
Renesas Electronics America
Quantity:
135
M
R
R
1
e
E
Figure 18.12 Flow Chart of Program Command
. v
6
J
18.7.3 Clear Status Register Command (50
18.7.4 Program Command (40
0
C
2
9
The clear status register command clears the status register to “0”.
By writing ‘xx50
SR5 bits in the status register are set to “0”.
The program command writes 2-byte data to the flash memory.
Auto program operation (data program and verify) start by writing ‘xx40
to the write address specified in the second bus cycle. The address value specified in the first bus cycle
must be the same even address as the write address secified in the second bus cycle.
The FMR00 bit in the FMR0 register indicates whether an auto-programming operation has been com-
pleted. The FMR00 bit is set to “0” during the auto-program and “1” when the auto-program operation is
completed.
After the completion of auto-program operation, the FMR06 bit in the FMR0 register indicates whether or
not the auto-program operation has been successfully completed. (Refer to 18.8.4 Full Status Check).
Also, each block can disable programming command (Refer to Table 18.4).
An address that is already written cannot be altered or rewritten.
When commands other than the program command are executed immediately after executing the pro-
gram command, set the same address as the write address specified in the second bus cycle of the
program command, to the specified address value in the first bus cycle of the following command.
In EW mode 1, do not execute this command on the blocks where the rewrite control program is allo-
cated.
In EW mode 0, the microcomputer enters read status register mode as soon as the auto-program opera-
tion starts and the status register can be read. The SR7 bit in the status register is set to “0” as soon as the
auto-program operation starts. This bit is set to “1” when the auto-program operation is completed. The
microcomputer remains in read status register mode until the read array command is written. After
completion of the auto-program operation, the status register indicates whether or not the auto-program
operation has been successfully completed.
2 /
0 .
B
0
8
0
0
G
4
J
7
a
o r
0 -
. n
u
2
3
p
0
, 1
0
(
M
2
0
1
0
6
16
7
C
2 /
’ in the first bus cycle, and the FMR06 to FMR07 bits in the FMR0 register and SR4 to
page 315
, 8
M
NOTES:
1
6
1. Write the command code and data at even address.
2. Refer to Figure 18.15 .
C
2 /
f o
8
3
) B
8
5
Write data to the write address
Write command code "xx40
16
)
the write address
Full status check
Program completed
FMR00=1?
Start
YES
16
)
(2)
(1)
NO
16
" to
(1)
16
’ in the first bus cycle and data
18. Flash Memory Version

Related parts for M30280F6HP