ADUM1250_VD AD [Analog Devices], ADUM1250_VD Datasheet - Page 5

no-image

ADUM1250_VD

Manufacturer Part Number
ADUM1250_VD
Description
Hot Swappable, Dual I2C Isolators
Manufacturer
AD [Analog Devices]
Datasheet
PACKAGE CHARACTERISTICS
Table 3.
Parameter
Resistance (Input to Output)
Capacitance (Input to Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
1
REGULATORY INFORMATION
The ADuM1250/ADuM1251 have been approved by the organizations listed in Table 4.
Table 4.
UL
Recognized under 1577 Component
Recognition Program
Single/basic 2500 V rms isolation voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 5.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Maximum Working Voltage Compatible with
The device is considered a 2-terminal device; Pin 1 through Pin 4 are shorted together, and Pin 5 through Pin 8 are shorted together.
In accordance with UL 1577, each ADuM125x is proof tested by applying an insulation test voltage ≥3000 V rms for 1 second (current leakage detection limit = 5 µA).
In accordance with DIN V VDE V 0884-10, each ADuM125x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
50 Years Service Life
1
1
1
CSA
Approved under CSA Component
Acceptance Notice #5A
Reinforced insulation per CSA 60950-1-03 and
IEC 60950-1, 125 V rms (177 V peak) maximum
working voltage
Basic insulation per CSA 60950-1-03 and
IEC 60950-1, 400 V rms (566 V peak) maximum
working voltage
File 205078
Symbol
R
C
C
θ
θ
I-O
JCI
JCO
I-O
I
Symbol
L(I01)
L(I02)
CTI
V
IORM
Min
Rev. D | Page 5 of 12
Value
2500
4.90 min
4.01 min
0.017 min
>175
IIIa
565
Typ
10
1.0
4.0
46
41
12
Max
Unit
V rms
mm
mm
mm
V
V peak
Unit
Ω
pF
pF
°C/W
°C/W
Conditions
1-minute duration
Measured from input terminals to output
terminals, shortest distance through air
Measured from input terminals to output
terminals, shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Continuous peak voltage across the isolation barrier
Test Conditions
f = 1 MHz
Thermocouple located at center of package underside
VDE
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
Reinforced insulation, 560 V peak
File 2471900-4880-0001
ADuM1250/ADuM1251
2

Related parts for ADUM1250_VD