ADUM1310ARWZ-RL1 AD [Analog Devices], ADUM1310ARWZ-RL1 Datasheet - Page 10

no-image

ADUM1310ARWZ-RL1

Manufacturer Part Number
ADUM1310ARWZ-RL1
Description
Triple-Channel Digital Isolators
Manufacturer
AD [Analog Devices]
Datasheet
ADuM1310/ADuM1311
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-to-Output)
Capacitance (Input-to-Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance
1
2
REGULATORY INFORMATION
The ADuM131x have been approved by the organizations listed in Table 5.
Table 5.
UL
Recognized under 1577 component
recognition program
Single/basic insulation,
2500 V rms isolation voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Device considered a 2-terminal device; Pin 1, Pin 2, Pin 3, Pin 4, Pin 5, Pin 6, Pin 7, and Pin 8 shorted together and Pin 9, Pin 10, Pin 11, Pin 12, Pin 13, Pin 14, Pin 15, and
Pin 16 shorted together.
Input capacitance is from any input data pin to ground.
In accordance with UL 1577, each ADuM131x is proof tested by applying an insulation test voltage ≥3000 V rms for 1 sec (current leakage detection limit = 5 μA).
In accordance with DIN EN 60747-5-2, each ADuM131x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN EN 60747-5-2 approval.
Side 1
Side 2
1
2
1
1
CSA
Approved under CSA Component
Acceptance Notice #5A
Reinforced insulation per CSA 60950-1-
03 and IEC 60950-1,
400 V rms maximum working voltage
File 205078
Symbol
R
C
C
θ
θ
I-O
JCI
JCO
I-O
I
Symbol Value
L(I01)
L(I02)
CTI
Rev. F | Page 10 of 20
Min
2500
7.7 min
8.1 min
0.017 min mm
>175
IIIa
Typ
10
2.2
4.0
33
28
12
Unit
V rms 1 minute duration
mm
mm
V
Max
VDE
Certified according to DIN EN 60747-5-2
(VDE 0884 Part 2): 2003-01
Basic insulation, 560 V peak
Complies with DIN EN 60747-5-2 (VDE 0884 Part 2): 2003-01,
DIN EN 60950 (VDE 0805): 2001-12; EN 60950: 2000
Reinforced insulation, 560 V peak
File 2471900-4880-0001
Conditions
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
2
Unit
Ω
pF
pF
°C/W
°C/W
Test Conditions
Thermocouple located at center of
package underside
f = 1 MHz

Related parts for ADUM1310ARWZ-RL1