SAF82525 Infineon Technologies AG, SAF82525 Datasheet - Page 94

no-image

SAF82525

Manufacturer Part Number
SAF82525
Description
Data Communications ICs
Manufacturer
Infineon Technologies AG
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAF82525
Manufacturer:
S
Quantity:
32
Part Number:
SAF82525H
Manufacturer:
NEC
Quantity:
10
Part Number:
SAF82525HV2.1
Manufacturer:
INFINEON
Quantity:
490
Part Number:
SAF82525N
Quantity:
2 000
Part Number:
SAF82525N
Quantity:
5 510
Part Number:
SAF82525N
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
SAF82525N V2.1G-HSCX
Quantity:
1 500
Part Number:
SAF82525N-V2.1
Manufacturer:
INTEL
Quantity:
20 000
Part Number:
SAF82525N-V21
Manufacturer:
Infineon Technologies
Quantity:
10 000
Part Number:
SAF82525NV2.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
SAF82525NV2.2
0
Receive Address Byte High Register 2 (WRITE)
RAH2
RAH2 … Value of second individual programmable high address byte.
MCS … Module Count Select; valid in auto-mode only.
Note:
Receive Address Byte High Register 1 (WRITE)
RAH1
In operating modes that provide high byte address recognition, the high byte of the received
address is compared with the individual programmable values in RAH1, or RAH2.
RAH1 … Value of the first individual high address byte
CRI … Command/Response Interpretation (auto-mode and non-auto mode only)
The setting of the CRI bit affects the meaning of the C/R bit in RSTA as follows:
C/R meaning
Commands received
Responses received
Important: If the 1 byte address field is selected in auto-mode, RAH1 must be set to 00
Semiconductor Group
The MCS bit adjusts the control field format according to the HDLC (ISDN/LAPD).
0 … basic operation (modulo 8)
1 … extended operation (modulo 128)
When modulo 128 is selected, in auto-mode the "RHCR" register contains compressed
information of the extended control field (see RHCR, register description). RAH1, RAH2
registers are used in auto and non-auto operating modes when a 2-byte address field
has been selected (MODE.ADM = 1) and in the transparent mode 0.
RAH2 has to be initialized.
CRI = 1
70
7
0
1
C/R value
CRI = 0
RAH2
RAH1
1
0
94
MCS
CRI
1
0
0
0
0
SAB 82525