D38999/49 Defense Supply Center, D38999/49 Datasheet - Page 41

no-image

D38999/49

Manufacturer Part Number
D38999/49
Description
D38999K / D38999J 500 Cycle Contact
Manufacturer
Defense Supply Center
Datasheet
applicable test(s) specified. Connectors shall be mounted on the vibration table by normal means. All
contacts shall carry a test current of 100 milliamperes maximum and shall be continuously monitored for
discontinuities throughout the test. A detector capable of detecting any discontinuities in excess of 1
microsecond shall be used. All series I and II connectors shall have the wire bundles clamped to fixed
points at least 8 inches (203.2 mm) behind the connector. All series I, III, and IV plugs shall have an
accessory load fixture in accordance with figure 24 attached during vibration.
2005 of MIL-STD-1344. The following details shall apply:
vibration as indicated:
Means may be provided to relieve hermetic solder termination’s, and jumper wires may be used between
contacts.
motion from 10 to 2,000 Hz in each of three mutually perpendicular axes. The level of vibration shall be a
velocity of 254 mm/sec from 10-50 Hz; 1.5 mm double amplitude from 50-140 Hz, and 60 G from 140-2,000
Hz. The entire frequency range from 10-2,000 Hz and back shall be traversed in 20 minutes. The vibration
shall be applied for a duration of 12 hours in each of the three mutually perpendicular axes for a total of 36
hours. Each axis of vibration shall be accomplished by vibrating for 4 hours at ambient room temperature,
4 hours at -55 C ±5 C, and 4 hours at +175 C ±5 C for classes J, X and W, and 200 C ±5 C for classes C,
F, G, H, K, N, M, R, S, and Y.
204, test condition G, of MIL-STD-202.
method 2005 of MIL-STD-1344. The following details shall apply:
4.5.22.2 Vibration (series I, III, and IV). Connector samples shall be divided equally and subjected to
4.5.22.2.2 Sine vibration (series I and IV). Connectors shall be subjected to the test specified in method
4.5.22.2.3 Random vibration (series I, III, and IV). Connectors shall be subjected to the test specified in
4.5.22 Vibration (qualification only) (see 3.26). Wired and mated connectors shall be subjected to the
4.5.22.1 Random vibration (series II). Connectors shall be subjected to the test specified in method
4.5.22.2.1 Sine vibration (series III). Connector samples shall be subjected to a simple harmonic
a. Test condition VI, letter "J", except class Y shall be tested to letter "G".
b. Duration shall be 8 hours in the longitudinal direction and 8 hours in a perpendicular direction for
c. Means may be provided to relieve hermetic solder termination’s, and jumper wires may be used
a. Series I:
b. Series III:
c. Series IV:
a. Test condition VI - Letter "J". Series III at elevated temperature and series I and IV at ambient
between contacts.
a total of 16 hours.
Sine vibration (see 4.5.22.2.2).
Random vibration (see 4.5.22.2.3).
Random vibration (see 4.5.22.2.4).
Sine vibration (see 4.5.22.2.1).
Random vibration (see 4.5.22.2.3).
Random vibration (see 4.5.22.2.4).
Sine vibration (see 4.5.22.2.2).
Random vibration (see 4.5.22.2.3).
Random vibration (see 4.5.22.2.4).
temperature.
MIL-DTL-38999K
41