Table 42 - Circular Buffer Accumulate Control
7
6
5
4
3
2
1
0
START0
START0
START1
START1
STOP0
STOP0
STOP1
STOP1
Name
Word (Page 2, Address 12H)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
Start Receive Circular Buffer Zero. If
one, circular buffer zero will start to
accumulate data when a mismatch is
made between the selected received
data and the data of the code detect
word. If zero, this feature is disabled.
Start Receive Circular Buffer Zero. If
one, circular buffer zero will start to
accumulate data when a positive
match is made between the selected
received data and the data of the
code detect word. If zero, this feature
is disabled.
Start Receive Circular Buffer One. If
one, circular buffer one will start to
accumulate data when a mismatch is
made between the selected received
data and the data of the code detect
word. If zero, this feature is disabled.
Start Receive Circular Buffer One. If
one, circular buffer one will start to
accumulate data when a positive
match is made between the selected
received data and the data of the
code detect word. If zero, this feature
is disabled.
Stop Receive Circular Buffer Zero. If
one, circular buffer zero will stop
accumulating data when a mismatch
is
received data and the data of the
code detect word. If zero, this feature
is disabled.
Stop Receive Circular Buffer Zero. If
one, circular buffer zero will stop
accumulating data when a positive
match is made between the selected
received data and the data of the
code detect word. If zero, this feature
is disabled.
Stop Receive Circular Buffer One. If
one, circular buffer one will stop
accumulating data when a mismatch
is
received data and the data of the
code detect word. If zero, this feature
is disabled.
Stop Receive Circular Buffer One. If
one, circular buffer one will stop
accumulating data when a positive
match is made between the selected
received data and the data of the
code detect word. If zero, this feature
is disabled.
made
made
Functional Description
between
between
the
the
selected
selected
Table 45 - RAI and Continuous CRC Error Counter
7 - 6
7 - 0
7 - 0
Bit
Bit
Bit
5
4
3
2
1
0
Table 43 - Counter Load Control Word
Table 44 - Bit Error Rate Load Word
Load Word (Page 2, Address 19H)
LDCRC
LDBER
LDBPV
Name
BRLD7
BRLD0
RCLD7
RCLD0
LDEC
LDRC
Name
LDEF
Name
(Valid in ST-BUS mode only)
(0)
(0)
(0)
(0)
(0)
(0)
---
-
-
(Page 2, Address 15H)
(Page 2, Address 18H)
Unused.
CRC-4 Error Load
loaded into the CRC-4 Error counter
when this bit is changed from low to
high.
E-bit Error Load Word. Data is
loaded into the E-bit Error counter
when this bit is changed from low to
high.
Bipolar Violation Load Word. Data is
loaded into the Bipolar Violation
counter when this bit is changed from
low to high.
Errored
Word. Data is loaded into the Errored
Frame Alignment counter when this
bit is changed from low to high.
RAI and Continuous CRC Error Load
Word. Data is loaded into the RAI
and Continuous CRC Error counter
when this bit is changed from low to
high.
Bit Error Rate Load Word. Data is
loaded into the eight bit BER counter
when this bit is changed from low to
high.
Bit Error Rate Load Word. This bit
pattern is loaded into the bit error
rate counter when LDBER is toggled
(valid in ST-BUS mode only).
RAI and Continuous CRC Error Load
Word. This bit pattern is loaded into
the RAI and continuous CRC error
counter when LDRC is toggled (valid
in ST-BUS mode only).
Functional Description
Functional Description
Functional Description
Frame
Alignment
Word. Data is
Load