ZL50074GAC ZARLINK [Zarlink Semiconductor Inc], ZL50074GAC Datasheet - Page 9

no-image

ZL50074GAC

Manufacturer Part Number
ZL50074GAC
Description
32 K x 32 K Channel TDM Switch with 128 Input and 128 Output Streams
Manufacturer
ZARLINK [Zarlink Semiconductor Inc]
Datasheet
Pin Description (continued)
AB19, W17, W19, U19, R19,
N4, P5, Y1, Y2, W5, Y5, V9,
Y17, AA19, V18, Y21, W22,
W16, AA20, U18, V20, T20,
C4, B2, D2, H3, E1, K2, L4,
Y7, AB7, Y10, AB12, AB16,
B3, E4, H5, J4, K5, M5, N5,
D6, F5, E3, D1, J3, L5, M3,
D5, B1, F3, E2, F1, K1, N1,
E6, D3, H4, F2, K4, L3, N2,
M4, U1, U3, AA1, AA2, V7,
R1, V1, T4, W3, AB1, AA4,
W8, AB6, V10, AB11, Y14,
AA6, Y9, AB10, V11, W14,
AB5, AB8, W11, V12, Y15,
T21, N19, M19, K22, G22,
P18, P21, M21, K20, K18,
U22, N20, M20, K21, J18,
U20, P19, R22, N22, L18,
U14, V16, Y20, T18, V21,
P3, R4, W2, V4, V6, AB3,
H21, G20, F20, D20, E16
AA8, AA10, AA12, AA15,
T22, N18, L22, J22, J19,
AB18, U16, AB21, W20,
R2, T3, V3, U5, Y4, U8,
H19, C22, E19, C18
F21, G18, D19, B19
H17, D21, F18, A21
H18, F19, E18, F14
Pin
SToA0-31
SToB0-31
SToC0-31
STiC0-31
STiD0-31
Name
Serial TDM Input Data ’C’ Streams (5 V Tolerant Input with
Internal Pull-down)
32 serial TDM input data streams. All streams are at the same rate:
16.384 Mbps or 8.192 Mbps, programmed by the Global Rate
Control Register (Section 12.8). These streams are unused when
the device data rate is 65.536 Mbps or 32.678 Mbps.
The data streams can be selected to be either inverted or
non-inverted, programmed by the Group Control Registers (Section
12.3).
Unused inputs are pulled low by internal pull-down resistors and
may be left unconnected.
Serial TDM Input Data ’D’ Streams (5 V Tolerant Input with
Internal Pull-down)
32 serial TDM input data streams. All streams are at the same rate:
16.384 Mbps or 8.192 Mbps, programmed by the Global Rate
Control Register (Section 12.8). These streams are unused when
the device data rate is 65.536 Mbps or 32.678 Mbps.
The data streams can be selected to be either inverted or
non-inverted, programmed by the Group Control Registers (Section
12.3).
Unused inputs are pulled low by internal pull-down resistors and
may be left unconnected.
Serial TDM Output Data ’A’ Streams (5 V Tolerant, 3.3 V
Tri-state Slew-Rate Controlled Outputs)
32 serial TDM output data streams. All streams are at the same
rate: 65.536 Mbps, 32.678 Mbps, 16.384 Mbps or 8.192 Mbps,
programmed by the Global Rate Control Register (Section 12.8).
The data streams can be selected to be either inverted or
non-inverted, programmed by the Group Control Registers (Section
12.3).
Serial TDM Output Data ’B’ Streams (5 V Tolerant, 3.3 V
Tri-state Slew-Rate Controlled Outputs)
32 serial TDM output data streams. All streams are at the same
rate: 32.678 Mbps, 16.384 Mbps or 8.192 Mbps, programmed by
the Global Rate Control Register (Section 12.8). These streams are
unused when the device data rate is 65.536 Mbps.
The data streams can be selected to be either inverted or
non-inverted, programmed by the Group Control Registers (Section
12.3).
Unused outputs are tristated and may be left unconnected.
Serial TDM Output Data ’C’ Streams (5 V Tolerant, 3.3 V
Tri-state Slew-Rate Controlled Outputs)
32 serial TDM output data streams. All streams are at the same
rate: 16.384 Mbps or 8.192 Mbps, programmed by the Global Rate
Control Register (Section 12.8). These streams are unused when
the device data rate is 65.536 Mbps or 32.678 Mbps.
The data streams can be selected to be either inverted or
non-inverted, programmed by the Group Control Registers (Section
12.3).
Unused outputs are tristated and may be left unconnected.
Zarlink Semiconductor Inc.
ZL50074
9
Description
Data Sheet

Related parts for ZL50074GAC