LC104S1 ETC1 [List of Unclassifed Manufacturers], LC104S1 Datasheet - Page 27

no-image

LC104S1

Manufacturer Part Number
LC104S1
Description
PRELIMINARY SPECIFICATION
Manufacturer
ETC1 [List of Unclassifed Manufacturers]
Datasheet
10. IIS (Incoming Inspection Standard)
10.1. Inspection Method
10.2 Inspection Criteria
10.2. Dot Defect
10.1.1. Ambient conditions
10.1.2. Viewing distance
10.1.3. Viewing Angle
10.1.4. Measurement mode
10.2.1. Bright Dot
10.2.2. Dark Dot
10.2.3. Total amount of Dot Defects ----------------------- 15 Max(Combination)
Note) a. Every dot herein means Sub-Pixel (Each Red,Green, or Blue Color)
The inspection shall be conducted within normal viewing angle range.
a. Temperature
b. Humidity
c. Illumination
The distance between the LCM and the inspector’s eyes shall be at least 35Cm.
Refer to 14 pages for viewing angle.
Inspection method is based on transmissive mode only.
- R,G or B 1 dot
- Adjacent 2 dots ------------------------------------
- Total amount of Bright dots ---------------------- 10 Max
- Minimum Distance between bright dots ------ 20 mm, Max 2
Dots(sub-pixels) which appeared darkly in the screen when the LCM
displayed with bright pattern.
- 1 dot
- Adjacent 2 dots -------------------------------------
- Total amount of Dark dot ------------------------- 10 Max
- Minimum Distance between dark dots -------- 20 mm, Max 2
Dots(sub-pixels) which appeared brightly in the screen when the LCM
displayed with dark pattern.
b. Bright & Dark dots are larger than half sub-pixel.
(Dots smaller than half sub-pixel are not counted as a defect dots.)
-------------------------------------------------- 10 Max
: 20 ~ 25 ° C
: 65 ± 5 % RH
: Single 20W fluorescent lamp non-directive
------------------------------------ 10 Max
(300 to 700 Lux)
Vernissakatu 8A
01300 Vantaa, Finland
http://www.alpha.fi
Alpha Point Ltd.
2 Max (Horizontal only)
Liquid Crystal Display LC104S1-A1
2 Max (Horizontal only)
Tel.: +358-9-34 64 34 1
Fax: +358-9-34 64 34 2
SPECIFICATION
Page 27 / 28