4-2 • Using Banks
Note
Mode Select SW2
+
-
Operating Conventions For Function Tables
The following rules apply to the function tables that are used throughout this section:
Selecting Banks
Function Select switch functionality is divided into three banks of functions. Use the following steps
to select Bank A, B or C as required.
A
B
C
1. Rotate Function Select (SW1) to position 0. Note that position 0 is always used to
2. Toggle Mode Select (SW2) up or down to choose the desired bank. Three positions
3. The table below illustrates each switch function, along with the Heads-Up Display
1. No display - Adjustments are made using the Function Select and Mode Select
2. Heads-Up Display - Adjustments are made using Function Select and Mode
3. Terminal Display - Adjustments are made using Function Select and Mode
The label “ + ” instructs you to toggle the Mode Select switch (SW2) up
momentarily.
The label “ - ” instructs you to toggle the Mode Select switch (SW2) down
momentarily.
The label “ + (h) ” instructs you to hold the Mode Select switch (SW2) up for one
second.
The label “ - (h) ” instructs you to hold the Mode Select switch (SW2) down for one
second.
select the bank, regardless of the bank that you are currently using.
are available: Bank A, B or C.
label, the Status LED indication, and the default value. If you are not using a
display, be sure to verify your selection on the Status LED's.
Both the Heads-Up Display and the Comlink Display can be used
simultaneously.
switches, without the assistance of the Heads-Up Display or the Comlink
Display. Results should be confirmed with test equipment suitable for
measuring the parameter being adjusted (such as a waveform monitor or vector
scope).
Select switches in conjunction with the Heads-Up Display. Ensure that the
Heads-Up Display is enabled (Bank A, Position 1). Note that the display is
superimposed over all ADC-8032A video outputs.
Select switches in conjunction with the Comlink Display. Ensure that the
Comlink port is properly connected to a PC. Refer to Chapter 8, “Comlink”
for instructions.
Heads-up Display Label
BANK A
BANK B
BANK C
Table 2. Switch and Bank Selection
Status LED
BANK A
BANK B
BANK C
ADC-8032A User Manual (Iss. 04)
Default Bank
A
A
A