SPECIFICATIONS
1. Input signal
(1) Process value input signal:
Note: * FS: Full scale
(2) Analog input signal: 1 point
External set point
input signal
(3) Digital input signal: 1 point
Remote
acknowledge
signal
(4) Pulse width or pulse number input signal: 1 set (either one)
Pulse width input
signal
Pulse number in-
put signal
2. Output signal
(1) Analog output signal: 2 points
Compensated process
value signal
Set point output
signal
(2) Digital output signal: 5 points
Fault output
Remote request signal
High alarm output
Low alarm output
3. Indication, setting, operating functions
(1) Bargraph indication
Indication method
No. of segments
Range
Resolution
Scale length
Indicating mode
(2) Operation mode indication
Indicating method:
(3) Numerical value indication, setting
Indication method:
Voltage in-
put signal
current in-
put signal
Local mode output
PNF1
I
I
I
+
0
1 to 5V DC
4 to 20mA DC
R-ACK
CAS
PI
PI
One input selectable from the following
LED (green)
LED (red), name in 3 digits + numerical
value in 5 digits (negative code included)
+
R-REQ
KPV
SV
Green: L(local), R(remote)
FLT
1 to 5V DC
Contact input
(photo-coupler
insulation)
LS
H
L
Contact input
(photo-coupler
insulation)
PV indicator
LED (red)
101 + 2
0 to 100%, linear
1 %/FS
100mm
0 to 100% bargraph indication,
0 to 100% reverse bargraph indication,
dot indication, –50 to +50% deviation
indication
1 to 5V DC
Open-collector
output (photo-
coupler insula-
tion)
Input resistance,
1M
24V 2V DC can be
supplied to transmit-
ter only when AC
power is used
Input resistance, 1M
Allow. error 0.2%/FS
or more
ON 0V, OFF 24V
(input current, approx.
11mA/24 DC)
ON 0V, OFF 24V
(approx. 11mA/24V DC)
max. input frequency
500Hz
Output resistance, 1
or less
Allow. error 0 2%/FS
ON 0V, OFF 24V
( input current, approx.
11mA/24V DC)
SV indicator
LED (green)
101 + 2
0 to 100%, linear
1%/FS
100mm
Rated output,
30V x 0.1A DC,
max.
Allow. error
Allow. error
0.2%/FS*
0.2%/FS
or more
Contents of indication:
Setting method: By using F/S ,
(4) Setting functions
Fixed value setting method:
Remote setting method:
(5) Operation mode changeover
By using of R/L pushbutton on front panel
R
R
Note: * Balanceless bumpless by setting tracking speed
(6) Alarm functions
High/low alarm settable in industrial values for process value
input signal.
4. Power failure processing functions
Power failure detection:
During power failure:
Power failure recovery:
5. Self-diagnosis functions
Input signal abnormality:
Indication of abnormal contents:
6. Transmission functions
(1) Transmission items
(2) Transmission setting inhibit:
Supervisory items:
Setting operation items:
Parameter setting enable/inhibit can be designated by
transmission from the host. Designation is done by keys
on the front panel key.
L changeover
L changeover
Voltage signal*
Pulse width signal
(industrial value), high/low alarm, etc.
on front panel
panel.
sec/FS
tion.
minutes. Initial value of set point stored
in non-volatile memory (10 years expected
at ambient temperature of 50 C or less).
set within 5 minutes of power failure.
Recovery from power failure lasting
longer than 5 minutes is initial. **
cal values on front panel.
mode, alarm information, fault informa-
tion, various limiter values, constants, etc.
values, constants, etc.
Process value (industrial value), set point
Indication contents are selectable by F/S ,
By using of
Setting speed, approx. 40 sec/FS
By use of external set point signal
(voltage or pulse width input)
Tracking speed setting range; 0 to 900
Setting output held at power failure detec-
Data backed up by capacitor up to 5
Initial or continuous start mode can be
Note: ** Operation mode set at initial can be reg-
FLT lamp lights, FLT output contact "ON"
Cause of abnormality indicated in numeri-
PNF
Process variable, set point, operation
Host
Set point, operation mode, various limiter
,
host
PNF
istered
L: Local mode or R: Remote mode
keys on front panel.
,
Balanceless bumpless
Balance bumpless
Balanceless bumpless
,
pushbuttons on front
,
, ST keys

Related parts for EDS11-105E