EDS11-106E

Manufacturer Part Number
EDS11-106E
Description
FC SERIES RATIO SETTER
Manufacturer
FUJI [Fuji Electric]
Datasheet
control, and its set point signal is transmitted to a controller.
button operation system to provide reliable monitoring and
operating functions.
to 20mA DC input optionally.
FEATURES
1. High reliability
2. International standards
3. Front panel operation
FUNCTIONAL DIAGRAM
Process value
input (PV)
External set point
input (CAS or PI)
(1 to 5V DC,
pulse width,
or pulse number)
Remote
acknowledge
signal (R-ACK)
DATA SHEET
The FC series ratio setter is used to set ratio for ratio
This instrument uses a solid state indicator and a push-
It also accepts a thermocouple, a resistance bulb and a 4
This instrument is designed with few mechanical parts.
It is mainly composed of electronic parts such as a solid
state indicator which was formerly consisted of mechani-
cal parts.
This instrument is compact in size, conforming to inter-
national standards IEC. It operates on 24V DC power to
deliver 1 to 5V DC signals as recommended by IEC stand-
ards.
100 and 200V AC power are also available for conven-
ience of operation.
Process values and set points can be read accurately
with digital indications on panel front. Various parameter
settings and setting operations are also possible from
the front panel of the instrument.
Linearize
Square-root
extraction
FC SERIES RATIO SETTER
Limiter
B1
B2
B3
H
R
L
SV
SO = R X (SV+B
Filter
R
L
(PV–B
1
) + B
PV
3
) X
2
SV
Limiter
H
L
SO
KPV
2
ALM
SO
Local mode
output (LS)
Remote reques
(R-REQ)
Compensated
process value
signal (KPV)
Set point
output (SO)
Squared set
point output
(SO2)
Ratio output
signal (SV)
High alarm
output (H)
Low alarm
output (L)
Date
EDS11-106e
PNG1
Jul. 1, 1994

Related parts for EDS11-106E

EDS11-106E Summary of contents

Page 1

... H L (PV– PNG1 Local mode SO output (LS) Remote reques (R-REQ) Compensated process value signal (KPV) Set point output (SO) Squared set point output 2 SO (SO2) Ratio output signal (SV) High alarm output (H) KPV ALM Low alarm output (L) EDS11-106e Date Jul. 1, 1994 ...

Page 2

PNG1 SPECIFICATIONS 1. Ratio computing function Computing formula – Ratio factor and ratio bias: Setting range; –327.6 to 327.67% Computation ...

Page 3

Power failure recovery: Initial or continuous start mode can be set within 5 minutes of power failure. Recovery from power failure lasting longer than 5 minutes is done by initial. Note: ** Control mode at initialzation can be registered L: ...

Page 4

PNG1 OUTLINE DIAGRAM (Unit:mm) Terminal Terminal cover Support bracket 140 36 Panel cutout When mounting 1 unit +0 Panel thickness 8mm or less Mounting 200min. bracket 355 When mounting "n" units +1 (72.2n – ...

Page 5

CONNECTION DIAGRAM Block terminals (M4 screw) Process I+ 11 value (PV) input I– 12 (SC – (Local mode) 34 FLT Instrument power (AC) ...

Page 6

PNG1 COMMUNICATION CONNECTOR 1 SIG GND 6 2 SHLD(SD INH 8 RXD + 4 TXD+(T1) 9 RXD – 5 TXD–(T2) Yellow Green Brown Red 1 SIG GND 6 2 SHLD(SD INH 8 RXD + 4 TXD+(T1) ...

Related keywords