EDS11-106E FUJI [Fuji Electric], EDS11-106E Datasheet - Page 5

no-image

EDS11-106E

Manufacturer Part Number
EDS11-106E
Description
FC SERIES RATIO SETTER
Manufacturer
FUJI [Fuji Electric]
Datasheet
CONNECTION DIAGRAM
Block terminals (M4 screw)
Process
value
input
DO
(Local mode)
Connections for process value input terminal block
1 to 5V DC
The 5th digit of
code symbols
A
4 to 20mA DC
The 5th digit of
code symbols
B
4 to 20mA DC
with inner DC
power supply
of CC-S
The 5th digit of
code symbols
B
I+
(PV)
I–
(SC)
Instrument power (AC)
AC
LS
+
+
11
12
13
14
15
16
+
+
+
31
32
33
34
35
11
12
11
12
11
12
FLT
PI
PI
AC
I
o
+
31
31
31
DO
(FLT output)
(Pulse width
input or pulse
number input)
PC
60
AO
(Compensated process
value signal)
AO
(Set ratio output signal)
AO
(Set point output)
AO
(Squared set point
output)
AI, AO
Common bus
DO
(High alarm)
DO
(Low alarm)
Instrument power
(24V DC, AC power)
24V power
for DI, DO
Note: * Symbols for AC instrument power are VPO, PCO,
Thermocouple
The 5th digit of
code symbols
C,D,E,F
Resistance bulb
The 5th digit of
code symbols
G,W
approx. 24V DC (0.1A max.) output.
Earth
PCD
KPV
PC*
SO2
SC
SV
SO
H
G
L
51
52
53
54
55
56
57
58
59
60
61
62
+
71
72
73
74
75
76
77
78
79
80
81
82
R-REQ
R-ACK
CAS
VP*
VPD
SC
+
+
11
12
11
12
+
+
AI
(External set point)
AI, AO
common bus
DO
(Remote request)
DI
(Remote acknowledge)
Instrument power
(24V DC power, AC power)
24V power
for DI, DO
31
31
5

Related parts for EDS11-106E