Manufacturer Part Number
W3150A+
Description
Ethernet ICs ENET CONTR TCP/IP+MAC
Manufacturer
WIZnet
Datasheet

Specifications of W3150A+

Rohs
yes
Product
Ethernet Transceivers
Supply Voltage - Max
3.6 V
Supply Voltage - Min
3 V
Maximum Operating Temperature
+ 80 C
Package / Case
LQFP-64
Ethernet Connection Type
10Base-T, 100Base-TX
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
GWR (Gateway IP Address Register) [R/W] [0x0001 – 0x0004] [0x00]
This Register sets up the default gateway address.
Ex) in case of “192.168.0.1”
SUBR (Subnet Mask Register) [R/W] [0x0005 – 0x0008] [0x00]
This register sets up the subnet mask address.
Ex) in case of “255.255.255.0”
SHAR (Source Hardware Address Register) [R/W] [0x0009 – 0x000E] [0x00]
This register sets up the Source Hardware address.
Ex) In case of “00.08.DC.01.02.03”
SIPR (Source IP Address Register) [R/W] [0x000F – 0x0012] [0x00]
This register sets up the Source IP address.
Ex) in case of “192.168.0.3”
0x0009
192 (0xC0)
192 (0xC0)
255 (0xFF)
0x00
0x0001
0x0005
0x000F
1 : Enable Indirect bus I/F mode
If this bit is set as ‘1’, Indirect BUS I/F mode is set. For more detail, refer to 6.
Application Information, 6.1.2. Indirect Bus IF Mode.
0x000A
© Copyright 2006 WIZnet Co., Inc. All rights reserved.
0x08
168 (0xA8)
255 (0xFF)
168 (0xA8)
0x0002
0x0006
0x0010
0x000B
0xDC
- 20 -
255 (0xFF)
0 (0x00)
0 (0x00)
0x0003
0x0007
0x0011
0x000C
0x01
1 (0x01)
0 (0x00)
3 (0x03)
0x000D
0x0004
0x0008
0x0012
0x02
0x000E
0x03