ES-U-2016-RM EasySync, ES-U-2016-RM Datasheet - Page 21

no-image

ES-U-2016-RM

Manufacturer Part Number
ES-U-2016-RM
Description
USB Interface IC USB to 16 Ports RS422/RS485, Metal
Manufacturer
EasySync
Datasheet
5.6
This section applies to the following adapters:
See the General Notes and Warnings on page 14 before changing settings or opening the cover. The DIP
switches should be set to select the correct serial mode before connecting the converter to your RS-
232/RS-422/RS-485 serial bus.
DIP Switch Settings
On the outside of the unit, there are four DIP switches, which are used to select the required serial mode
(RS-232, RS-422 or RS-485).
Jumper Settings
Inside the unit, there is a 7x2 (14 pin) header block for each serial port. Jumpers are used to select
features such as 120 Ohm termination on Tx, Rx and CTS, and 750 Ohm biasing resistors on Tx and Rx.
You will need to open up the cover and set the jumpers as per the requirements of your application.
ES-U-3xxx-x
ES-U-3001-M
ES-U-3008-RM
ES-U-3016-RM
Jumper
11 - 12
13 - 14
RS-232
RS-422
RS-485
9 - 10
1 - 2
3 - 4
5 - 6
7 - 8
Table 10
Table 11
4 Wire with handshaking
Full Duplex (4 wire)
Half Duplex (2 wire) with Echo
Half Duplex (2 wire) without Echo
See the notes in section 5.1 before setting Termination and Biasing
Enable Tx+/- Termination with 120 Ohm. This jumper should be
populated for RS-485 half-Duplex mode
Pull-up Tx+ to VCC by 750 Ohm Bias resistor. This jumper should be
populated to enable pull-up of Tx+
Pull-down Tx- to GND by 750 Ohm Bias resistor This jumper should be
populated to enable pull-down of Tx-
Enable Rx+/- Termination with 120 Ohm. This jumper should be
populated for RS-422 and RS-485 Full-Duplex mode
Pull-up Rx+ to VCC by 750 Ohm Bias resistor. This jumper should be
populated to enable pull-up of Rx+
Pull-down Rx- to GND by 750 Ohm Bias resistor. This jumper should be
populated to enable pull-down of Rx-
Enable CTS Termination with 120 Ohm. This jumper should be populated
for RS-422 mode.
Operation Mode
©2010 - 2011 EasySYNC Ltd.
RS-232, RS-422 & RS-485 Mode Configuration
Jumpers to select termination and biasing
Function
OFF
ON
ON
ON
ON
S1
Document Reference No.: ES_000061
OFF
OFF
OFF
ON
ON
S2
USB to Serial Converters Manual
OFF
OFF
S3
ON
ON
ON
Clearance No.: ES
OFF
ON
ON
ON
ON
S4
Version 1.2
# 35
21