M24256-BRDW6TP STMicroelectronics, M24256-BRDW6TP Datasheet - Page 21

IC EEPROM 256KBIT 400KHZ 8TSSOP

M24256-BRDW6TP

Manufacturer Part Number
M24256-BRDW6TP
Description
IC EEPROM 256KBIT 400KHZ 8TSSOP
Manufacturer
STMicroelectronics
Datasheets

Specifications of M24256-BRDW6TP

Format - Memory
EEPROMs - Serial
Memory Type
EEPROM
Memory Size
256K (32K x 8)
Speed
400kHz
Interface
I²C, 2-Wire Serial
Voltage - Supply
1.8 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
8-TSSOP
Organization
32 K x 8
Interface Type
I2C
Maximum Clock Frequency
0.4 MHz
Access Time
900 ns
Supply Voltage (max)
5.5 V
Supply Voltage (min)
1.8 V
Maximum Operating Current
0.5 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
2.5 V, 3.3 V, 5 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-6347-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M24256-BRDW6TP
Manufacturer:
STMicroelectronics
Quantity:
49 478
Part Number:
M24256-BRDW6TP
Manufacturer:
ST
0
Part Number:
M24256-BRDW6TP
Manufacturer:
ST
Quantity:
300
Part Number:
M24256-BRDW6TP
Manufacturer:
ST
Quantity:
20 000
Part Number:
M24256-BRDW6TP
0
Company:
Part Number:
M24256-BRDW6TP
Quantity:
32 000
Part Number:
M24256-BRDW6TP.
Manufacturer:
ST
0
M24256-BF, M24256-BR, M24256-BW, M24256-DR
3.18
3.19
Reading the lock status (M24256-D only)
The locked/unlocked status of the Identification page can be checked by transmitting a
specific truncated command [Identification Page Write instruction + one data byte] to the
device. The device will return an acknowledge bit if the Identification page is unlocked,
otherwise a NoAck bit if the Identification page is locked.
Right after this, it is recommended to transmit to the device a Start condition followed by a
Stop condition, so that:
Acknowledge in Read mode
For all Read instructions, the device waits, after each byte read, for an acknowledgment
during the 9
time, the device terminates the data transfer and switches to its Standby mode.
Start: the truncated command is not executed because the Start condition resets the
device internal logic,
Stop: the device is then set back into Standby mode by the Stop condition.
th
bit time. If the bus master does not drive Serial Data (SDA) Low during this
Doc ID 6757 Rev 23
Device operation
21/42

Related parts for M24256-BRDW6TP