IS42S32400E-7TLI ISSI, Integrated Silicon Solution Inc, IS42S32400E-7TLI Datasheet - Page 16

no-image

IS42S32400E-7TLI

Manufacturer Part Number
IS42S32400E-7TLI
Description
IC SDRAM 128MBIT 143MHZ 86TSOP
Manufacturer
ISSI, Integrated Silicon Solution Inc
Type
SDRAMr
Datasheets

Specifications of IS42S32400E-7TLI

Format - Memory
RAM
Memory Type
SDRAM
Memory Size
128M (4Mx32)
Speed
143MHz
Interface
Parallel
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
86-TSOPII
Organization
4Mx32
Density
128Mb
Address Bus
14b
Access Time (max)
6.5/5.4ns
Maximum Clock Rate
143MHz
Operating Supply Voltage (typ)
3.3V
Package Type
TSOP-II
Operating Temp Range
-40C to 85C
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Supply Current
130mA
Pin Count
86
Mounting
Surface Mount
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS42S32400E-7TLI
Manufacturer:
CREE
Quantity:
11
Part Number:
IS42S32400E-7TLI
Manufacturer:
ISSI
Quantity:
1 080
Part Number:
IS42S32400E-7TLI
Manufacturer:
ISSI
Quantity:
20 000
IS42S32400E
AC ELECTRICAL CHARACTERISTICS
Notes:
1. The power-on sequence must be executed before starting memory operation.
2. measured with t
3. The reference level is 1.4V when measuring input signal timing. Rise and fall times are measured between V
16
Symbol Parameter
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
ck3
ck2
ac3
ac2
chi
cl
oh3
oh2
lz
hz
ds
dh
as
ah
cks
ckh
cs
ch
rc
ras
rp
rcd
rrd
dpl
dal
mrd
dde
xsr
t
ref
(max).
Clock Cycle Time
Access Time From CLK
CLK HIGH Level Width
CLK LOW Level Width
Output Data Hold Time
Output LOW Impedance Time
Output HIGH Impedance Time
Input Data Setup Time
Input Data Hold Time
Address Setup Time
Address Hold Time
CKE Setup Time
CKE Hold Time
Command Setup Time (CS, RAS, CAS, WE, DQM)
Command Hold Time (CS, RAS, CAS, WE, DQM)
Command Period (REF to REF / ACT to ACT)
Command Period (ACT to PRE)
Command Period (PRE to ACT)
Active Command To Read / Write Command Delay Time
Command Period (ACT [0] to ACT[1])
Input Data To Precharge
Command Delay time
Input Data To Active / Refresh
Command Delay time (During Auto-Precharge)
Mode Register Program Time
Power Down Exit Setup Time
Self-Refresh Exit Time
Transition Time
Refresh Cycle Time (4096)
t
= 1 ns. If clock rising time is longer than 1ns, (t
(2)
(2)
(2)
(2)
(2)
(2)
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
CAS Latency = 3
CAS Latency = 2
(1,2,3)
(2)
(2)
r
Min.
2.5
2.5
2.7
2.7
2.7
1.5
0.8
1.5
0.8
1.5
0.8
1.5
0.8
60
42
18
18
12
12
12
70
30
/2 - 0.5) ns should be added to the parameter.
6
8
0
6
1
-6
Max.
100K
5.4
6.5
5.4
10
64
Min.
67.5
2.5
2.5
2.7
2.7
1.5
0.8
1.5
0.8
1.5
0.8
1.5
0.8
7.5
10
45
20
20
14
14
15
70
34
7
3
0
1
-7
Integrated Silicon Solution, Inc. - www.issi.com
Max.
100K
5.4
6.5
5.4
10
64
ih
(min.) and V
Units
ms
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
il
Rev. 00C
08/01/08

Related parts for IS42S32400E-7TLI