ISL6141CB Intersil, ISL6141CB Datasheet - Page 12

IC CONTROLLER HOT PLUG 8-SOIC

ISL6141CB

Manufacturer Part Number
ISL6141CB
Description
IC CONTROLLER HOT PLUG 8-SOIC
Manufacturer
Intersil
Type
Hot-Swap Controllerr
Datasheet

Specifications of ISL6141CB

Applications
General Purpose, VoIP
Internal Switch(s)
No
Voltage - Supply
36 V ~ 72 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.154", 3.90mm Width)
Linear Misc Type
Negative Voltage
Package Type
SOIC N
Operating Supply Voltage (max)
80V
Operating Temperature (min)
0C
Operating Temperature (max)
70C
Operating Temperature Classification
Commercial
Product Depth (mm)
4mm
Product Height (mm)
1.5mm
Product Length (mm)
5mm
Mounting
Surface Mount
Pin Count
8
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISL6141CB-T
Manufacturer:
LSIOGIC
Quantity:
218
Part Number:
ISL6141CBZ
Manufacturer:
INTERSIL
Quantity:
20 000
R1 - Is the Over-Current sense resistor. If the input current is
high enough, such that the voltage drop across R1 exceeds
the SENSE comparator trip point (50mV nominal), the GATE
pin will be pulled lower (to ~4V) and current will be regulated
to 50mV/Rsense for approximately 600µs. The Over-Current
threshold is defined in Equation 3 below. If the 600µs time-
out period is exceeded the Over-Current latch will be set and
the FET will be turned off to protect the load from excessive
current. A typical value for R1 is 0.02Ω, which sets an Over-
Current trip point of; I
select the appropriate value for R1, the user must first
determine at what level of current it should trip, take into
account worst case variations for the trip point (50mV
±10mV = ±20%), and the tolerances of the resistor (typically
1% or 5%). Note that the Over-Current threshold should be
set above the inrush current level plus the expected load
current to avoid activating the current limit and time-out
circuitry during start-up. If the power good output is used to
enable an external module, the desired inrush current only
needs to be considered. One rule of thumb is to set the
Over-Current threshold 2-3 times higher than the normal
operating current.
Physical layout of R1 SENSE resistor is critical to avoid
the possibility of false over current events. Since it is in the
main input-to-output path, the traces should be wide enough
to support both the normal current, and up to the over-
current trip point. Ideally trace routing between the R1
resistor and the ISL6141/51 (pin 4 (V
is direct and as short as possible with zero current in the
sense lines. (See Figure 24).
CL - is the sum of all load capacitances, including the load’s
input capacitance itself. Its value is usually determined by
the needs of the load circuitry, and not the hot plug (although
there can be interaction). For example, if the load is a
regulator, then the capacitance may be chosen based on the
input requirements of that circuit (holding regulation under
current spikes or loading, filtering noise, etc.) The value
chosen will affect the peak inrush current. Note that in the
I
CORRECT
OC
To SENSE
FIGURE 24. SENSE RESISTOR LAYOUT GUIDELINES
and V
=
------------------- -
R
50mv
EE
sense
OC
SENSE RESISTOR
CURRENT
= V/R = 0.05/0.02 = 2.5 Amps. To
12
INCORRECT
EE
) and pin 5 (SENSE)
(EQ. 3)
ISL6141, ISL6151
case of a regulator, there may be capacitors on the output of
that circuit as well; these need to be added into the
capacitance calculation during inrush (unless the regulator is
delayed from operation by the PWRGD signal).
RL - is the equivalent resistive value of the load and
determines the normal operation current delivered through
the FET. It also affects some dynamic conditions (such as
the discharge time of the load capacitors during a power-
down). A typical value might be 48Ω (I = V/R = 48/48 = 1A).
R2, C1, R3, C2 - are related to the GATE driver, as it
controls the inrush current.
R2 prevents high frequency oscillations; 10Ω is a typical
value. R2 = 10Ω.
R3 and C2 act as a feedback network to control the inrush
current as shown in equation 4 below, where CL is the load
capacitance (including module input capacitance), and I
the GATE pin charging current, nominally 50µA.
Begin by choosing a value of acceptable inrush current for
the system, and then solve for C2.
C1 and R3 prevent Q1 from turning on momentarily when
power is first applied. Without them, C2 would pull the gate
of Q1 up to a voltage roughly equal to V
(where Cgs is the FET gate-source capacitance) before the
ISL6141/2 could power up and actively pull the gate low.
Place C1 in parallel with the gate capacitance of Q1; isolate
them from C2 by R3.
C1= [(Vinmax - Vth)/Vth] * (C2+Cgd) - where Vth is the
FET’s minimum gate threshold, Vinmax is the maximum
operating input voltage, and Cgd is the FET gate-drain
capacitance.
R3 - its value is not critical, a typical value of 18kΩ is
recommended but values down to 1KΩ can be used. Lower
values of R3 will add delay to the gate turn-on for hot
insertion and the single retry event following a hard fault.
Note that although this IC was designed for -48V systems, it
can also be used as a low-side switch for positive 48V
systems; the operation and components are usually similar.
One possible difference is the kind of level shifting that may
be needed to interface logic signals to the UV input (to reset
the latch) or PWRGD output. For example, many of the IC
functions are referenced to the IC substrate, connected to
the V
depending upon the polarity of the system. And input or
output logic (running at 5V or 3.3V or even lower) might be
externally referenced to either V
of GND.
EE
pin. But this pin may be considered -48V or GND,
I
inrush
=
I
PU
DD
×
or V
C
------ -
C
L
2
EE
EE
*C2/Cgs(Q1)
of the IC, instead
(EQ. 4)
PU
is

Related parts for ISL6141CB