AS1113-BQFT austriamicrosystems, AS1113-BQFT Datasheet - Page 17

no-image

AS1113-BQFT

Manufacturer Part Number
AS1113-BQFT
Description
IC DRIVER LED 16-CHAN 28-TQFN
Manufacturer
austriamicrosystems
Type
General Purposer
Datasheet

Specifications of AS1113-BQFT

Constant Current
Yes
Topology
16-Bit Shift Register, PWM
Number Of Outputs
16
Internal Driver
Yes
Type - Primary
General Purpose
Frequency
50MHz
Voltage - Supply
3 V ~ 5.5 V
Voltage - Output
15V
Mounting Type
Surface Mount
Package / Case
28-WQFN
Operating Temperature
-40°C ~ 85°C
Current - Output / Channel
50mA
Internal Switch(s)
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Efficiency
-
AS1113
Datasheet - A p p l i c a t i o n I n f o r m a t i o n
9 Application Information
Error Detection
The AS1113 features two types of error detection. The error detection can be used on-the-fly, for active LEDs, without
any delay, or by entering into low-current diagnosis mode.
Error Detection On-The-Fly
Error detection on-the-fly will output the status of active LEDs during operation. Without choosing an error mode this
will output the temperature flag at every input/output cycle. Triggering one clock pulse for open or two clock pulses for
short detection during error detection mode outputs the detailed open- or short-error report with the next input/output
cycle
Figure 18. Normal Operation with Error Detection During Operation – 64 Cascaded AS1113s
Error Detection with Low-Current Diagnosis Mode
This unique feature of the AS1113 uses an internal all 1s test pattern for a flicker free diagnosis of all LEDs. This error
detection mode can be started at the end of each input cycle
Figure 19. Low-Current Diagnosis Mode with Internal All 1s Test Pattern – 64 Cascaded AS1113s
www.austriamicrosystems.com/LED-Driver-ICs/AS1113
Display
Current
Current
Display
SDO
OEN
SDO
OEN
CLK
CLK
(see Figure
SDI
SDI
LD
LD
T/O or S Error Code
Acquisition of Error Status
T/O or S Error Code
18). LEDs turned off at test time are not tested and will show a logic "1" at the detailed error report.
Acquisition of Error Status
Rising Edge of OEN
Data0
Data1
Data0
1024x
Data2
1024x
Data1
Data0
≤ 50mA
Rising Edge of OEN
3x Clocks Low-
Current Mode
Clock for Error
Mode 0x/1x/2x
Use Internal All 1s
Test Pattern
GEF
≤ 0.8mA
Clock for Error
Mode 1x/2x
Falling Edge of LD; Error Register is
copied into Shift Register
GEF
Low-Current Diagnosis Mode
T/O or S Error Code
Falling Edge of LD; Error Register
is copied into Shift Register
Revision 1.04
Acquisition of Error Status
O or S Error Code from
All 1s Test Pattern
Data1
1024x
≤ 50mA
Data2
Data3
Rising Edge of OEN
(see Figure
1024x
Data1
Data2
Mode 0x/1x/2x
Clock for Error
19).
≤ 50mA
GEF
GEF
Falling Edge of LD; Error Register is
copied into Shift Register
GEF = Global Error Flag
T/O or S Error Code
Temperature Error Code
GEF = Global Error Flag
Data2
Data3
1024x
Data4
1024x
Data2
Data3
17 - 24

Related parts for AS1113-BQFT