MAX8688ALETG+ Maxim Integrated Products, MAX8688ALETG+ Datasheet - Page 32

IC PWR SUPPLY CTRLR/MONTR 24TQFN

MAX8688ALETG+

Manufacturer Part Number
MAX8688ALETG+
Description
IC PWR SUPPLY CTRLR/MONTR 24TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX8688ALETG+

Applications
Power Supply Controller/Monitor
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
6.7mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-TQFN Exposed Pad
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Operating Temperature Range
- 40 C to + 85 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Digital Power-Supply Controller/Monitor
with PMBus Interface
The MFR_VOUT_CORRECTION_RATE command sets
the frequency (Hz) at which the MAX8688 adjusts 1
LSB of DACOUT (0.5mV) after the voltage has entered
the regulation band.
The 2 data bytes are formatted as positive integers. Valid
values are from 1 to 65535. Setting this value to 0 dis-
ables the DACOUT adjustment in the regulation band.
The default MFR_VOUT_CORRECTION_RATE value is
10 which is equivalent to a correction rate of 1kHz.
Table 8. MFR_MODE Bit Definition (continued)
32
Correction Rate = 10kHz/MFR_VOUT_CORRECTION_RATE
BIT
5
4
3
2
1
0
______________________________________________________________________________________
MFR_VOUT_CORRECTION_RATE (D2h)
Input Range Select
Correction Bypass
Feedback Mode
ENOUT Polarity
EEPROM Lock
Clock Source
BIT NAME
Enable
Enable
Select
Select
Select
The EEPROM Lock Enable bit is used to protect external EEPROM data from being overwritten. When
this bit is set to 1, the STORE_DEFAULT_ALL command is ignored. The RESTORE_DEFAULT_ALL
command is still valid. When this bit is cleared to 0, the STORE_DEFAULT_ALL command initiates a
store configuration operation to the EEPROM attached to A1/SCLE and A2/SDAE.
Correction Bypass Enable. Setting this bit to 1 disables a correction algorithm made to voltage,
current, and temperature readings. Clearing this bit to 0 applies a correction algorithm to voltage,
current, and temperature measurement, thus resulting in high-accuracy readings. For optimal
operation, this bit should be cleared to 0.
The Input Range Select bit determines the input range of RS+ and RS-. Setting this bit to 1 extends
the input range to 5.5V. Clearing this bit to 0 sets the input range to 2.048V.
Prior to setting any voltage-related values, the user application must first configure the desired input
range. All voltage-related commands use the selected input range to convert the commanded value
into internal register values.
It is not recommended to change the input range selection while the POL is operating, since all
voltage-related commands continue to refer to the input range that was in use when the commanded
voltage was received. This results in unpredictable and catastrophic operation.
The ENOUT Polarity Select bit selects the ENOUT active-on polarity. Setting this bit to 1 configures the
ENOUT asserted on-state the same as the default startup state. Clearing this bit to 0 configures the
ENOUT deasserted off-state the same as the default startup state. In effect, writing a 1 to this bit
means that the asserted state of ENOUT is the default startup state. See the ENOUT Operation
section.
The Feedback Mode Select bit determines the MAX8688 operation mode. When this bit is set to 1, the
MAX8688 operates in the feedback mode while when cleared to 0, the MAX8688 operates in the
REFIN mode.
The Clock Source Select bit determines the MAX8688 reference clock time source. When the Clock
Source Select bit is set to 1, an external clock must be supplied to CLKIO and is used as the
MAX8688 reference clock. When this bit is cleared to 0, an internal clock is used.
The MFR_SAMPLE_RATE command sets the frequency
(Hz) at which the POL output voltage, output current,
and temperature fault/warning conditions are monitored.
The 2 data bytes are formatted as positive integers.
Valid values are from 1 to 65535. Setting this value to 0
disables all fault/warning monitoring.
The default MFR_SAMPLE_RATE value is 50 which is
equivalent to a sample rate of 200Hz.
Monitor Sample Rate =10kHz/MFR_SAMPLE_RATE
DESCRIPTION