MAX16066ETL+ Maxim Integrated Products, MAX16066ETL+ Datasheet - Page 13

no-image

MAX16066ETL+

Manufacturer Part Number
MAX16066ETL+
Description
IC SYSTEM MANAGER 8CH 40-TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX16066ETL+

Applications
Power Supply Monitor, Sequencer
Voltage - Supply
2.8 V ~ 14 V
Current - Supply
4.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
40-VQFN Exposed Pad, 40-HVQFN, 40-SQFN, 40-DHVQFN
Number Of Voltages Monitored
8
Undervoltage Threshold
2.7 V
Manual Reset
Resettable
Watchdog
Yes
Battery Backup Switching
No
Power-up Reset Delay (typ)
200 us
Supply Voltage (max)
14 V
Supply Voltage (min)
2.8 V
Supply Current (typ)
10 mA
Maximum Power Dissipation
2105 mW
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Chip Enable Signals
No
Internal Hysteresis
Yes
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
of the EN comparator output or the software enable bit.
If operating in latch-on fault mode, toggle EN or toggle
the Software Enable bit to clear the latch condition and
restart the device once the fault condition has been
removed.
To initiate secondary sequencing and monitoring set the
software enable r73h[1] bit to 1. Additionally, if GPIO_ is
configured as EN2 then both the software enable 2 bit and
EN2 must be high. To power-down and disable monitor-
ing, either drive EN2 low or set the Software Enable2 bit to
‘0.’ See Table 2 for the software enable bit configurations.
When a fault condition occurs during the power-up cycle,
the EN_OUT_ outputs are powered down immediately,
independent of the state of EN2. Drive EN2 low to begin
the secondary power-down sequence. When EN2 is driv-
Table
Table
12-Channel/8-Channel, Flash-Configurable System
REGISTER
ADDRESS
REGISTER
ADDRESS
73h
7Ah
7Bh
7Ch
7Dh
77h
78h
79h
2. Software Enable Configurations
3. Slot Delay Register
ADDRESS
FLASH
Managers with Nonvolatile Fault Registers
______________________________________________________________________________________
273h
ADDRESS
FLASH
27Ah
27Bh
27Ch
27Dh
277h
278h
279h
BIT RANGE
[0]
[1]
[2]
[3]
[4]
BIT RANGE
[3:0]
[7:4]
[3:0]
[7:4]
[3:0]
[7:4]
[3:0]
[7:4]
[3:0]
[7:4]
[3:0]
[7:4]
[3:0]
[7:4]
Software enable 1 (primary sequence)
Software enable 2 (secondary sequence)
1 = Margin mode enabled
Early warning threshold select
0 = Early warning is undervoltage
1 = Early warning is overvoltage
Independent watchdog mode enable
1 = Watchdog timer is independent of sequencer
0 = Watchdog timer boots after sequence completes
Sequence Slot 0 Delay
Sequence Slot 1 Delay
Sequence Slot 2 Delay
Sequence Slot 3 Delay
Sequence Slot 4 Delay
Sequence Slot 5 Delay
Sequence Slot 6 Delay
Sequence Slot 7 Delay
Sequence Slot 8 Delay
Sequence Slot 9 Delay
Sequence Slot 10 Delay
Sequence Slot 11 Delay
Sequence Slot 12 Delay
Grouped Sequence Split Location, Final Slot of Primary Sequence
en high during the power-down sequence, the sequence
state machine continues the power-down sequence until
the secondary channels are powered off and then the
device immediately begins the power-up sequence.
An enabled MON_ input can be assigned to a slot
ranging from Slot 1 to Slot 12. EN_OUT_s are always
asserted at the beginning of a slot. The supply volt-
ages connected to the MON_ inputs must exceed the
undervoltage threshold before the programmed timeout
period expires otherwise a fault condition will occur. The
undervoltage threshold checking cannot be disabled
during power-up and power-down. See Tables 5 and
6 for the MON_ slot assignment bits. The programmed
DESCRIPTION
DESCRIPTION
Monitoring Inputs While Sequencing
13